12
mate gates in compliance with Machin-
ery Directive 2006/42/EC.
- The installer must check that all require-
ments in the com plete automation pre-
scribed in EN 12453 and EN 12445 are
satisfied.
- IMPORTANT: In order to obtain the
required safety level, (EN 12978) the
device must be used in conjunction with
control units equipped with the function
to test the security devices and activate
the “Test” function on the RTX2251
(Base) device.
- The control unit has no section-
ing device for the 230 Vac electri-
cal supply, therefore the installer
must provide a sectioning device. An
omnipolar switch with overvoltage
category III. This must be positioned
so that is protected against acciden-
tal closure as set for in point 5.2.9 of
EN 12453.
- Carefully choose the place of installa-
tion to obtain excellent radio system
functioning. Capacity is not only related
to the device technical data, but also
varies depending on the site’s radio-
electric conditions.
- The RTX 2251 device is equipped with
rigid wire section antenna. Connect
an RG58 50 OHM coaxial cable tuned
antenna if wanting to increase sensi-
tivity. Place the antenna externally in
clearly visible points and away from
metal structures.
- It is not possible to install two RTX 2251
(Base) Transceiver Devices that are not
at least 5 m away from each other.