BeLED Flashing/Acoustic Beacon
Flashing Beacon with integrated acoustic warning device,
available in various power supply voltage models, for visual
and acoustic signalling for movement automations such as
gates, garage doors and more.
- Mod.
BeLED 230VAC
: 230V~ 50/60Hz 4W max.
- Mod.
BeLED 12-24V AC-DC
: 12-24V AC-DC 4W max.
T
ECHNICAL
D
ATA
- Power supply:
see model
- 4 x 1W LED :
4W Max.
- Working temperature:
-10
÷
55°C
- Dimensions: 140 x 100 x 70 mm.
- Container: PMMA - ABS UL94V-0 ( IP54 )
I
NSTALLATION
OF
THE
F
LASHING
BEACON
For excellent functioning, it is very important to choose the
place of installation carefully. Verify that the chosen surface is
capable of guaranteeing stable fixing. Verify that the chosen
position can be accessed easily for future maintenance
operations.
I
NITIAL
F
UNCTIONING
C
ONDITION
The device must be exclusively connected to a source of
power that is suitable based on the model that was purchased;
a flashing electronic circuit is already integrated inside of it.
OPERATING FEATURES:
The flashing beacon is made of a transparent dome that
protects internal circuits and correctly diffuse light emitted by
the LEDs, and a base used for fixing it and passing cables.
When the device is active it warns the user that automation is
in movement using the luminous and acoustic signals,
depending on the settings.
SOUND SETTINGS:
Using the J1 Jumper it is possible to activate or
deactivate the acoustic signal as follows:
J1 not inserted
: the device is supplied from the factory
in this mode. The flashing is accompanied by an acoustic
signal whose tone and level is high.
J1 position 1 - 2
: the flashing is accompanied by an
acoustic signal whose tone and level is lower.
J1 position 2 - 3
: the acoustic signal is disabled.
MANOEUVRE COUNTER SETTINGS:
Based on the position of the SW1 dip switches, the device
counts a determined number of manoeuvres (switch on) until is
signals the need for maintenance. Once the set number of
manoeuvres has been reached, flashing is replaced by a fixed
light.
Counter = OFF 5,000 cycles 10,000 cycles 20,000 cycles
Counter = OFF:
the device is supplied from the factory
with the manoeuvre counter disabled. The flashing
beacon will continue to work without any limit in
manoeuvres, with flashing and acoustic signals,
depending on the settings. Activate the flashing beacon
at least once in this mode to reset the manoeuvre
counter.
No. 5,000 cycles:
The device functions normally with
flashing and acoustic signalling, if set, until it reaches
5,000 cycles (switch on), subsequently it continues the
visual and acoustic signalling, depending on the settings,
but the light it emits is fixed and no longer intermittent.
This state remains until the switches are brought to OFF
and the device is activated at least once. In order to start
a new count, set the SW1 Switch once again at the
desired number of manoeuvres.
No. 10,000 cycles:
The device functions normally with
flashing and acoustic signalling, if set, until it reaches
10,000 cycles (switch on), subsequently it continues the
visual and acoustic signalling, depending on the settings,
but the light it emits is fixed and no longer intermittent.
This state remains until the switches are brought to OFF
and the device is activated at least once. In order to start
a new count, set the SW1 Switch once again at the
desired number of manoeuvres.
No. 20,000 cycles:
The device functions normally with
flashing and acoustic signalling, if set, until it reaches
20,000 cycles (switch on), subsequently it continues the
visual and acoustic signalling, depending on the settings,
but the light it emits is fixed and no longer intermittent.
This state remains until the switches are brought to OFF
and the device is activated at least once. In order to start
a new count, set the SW1 Switch once again at the
desired number of manoeuvres.
I
MPORTANT
FOR
THE
INSTALLER
1
Rev. 1.0 26/05/2010
GB