background image

E

ASY

 L

IGHT

 T

WILIGHT

 S

WITCH

Easy   Light   twilight   switch,   makes   it   possible   to   carry   out 
controls   without   having   light,   there   are   various   operational 
modes and types of power supply.
- Mod.   

Easy Light:

                     Power supply  12-24 VAC-DC

- Mod.   

Easy Light 230V:

           Power supply            230VAC

T

ECHNICAL

 D

ATA

- Power supply:

See model

- Max. consumption:

2W

- Relay Contact:

30VDC 10A

- Working temperature:

-10÷55°C

- Dimensions:

80x54x38mm

- Protection rating:

IP 54

C

ONNECTIONS

 

OF

 

THE

 CN1 T

ERMINAL

 

BOARD

1: Power supply 230VAC
2: Power supply 230VAC

C

ONNECTIONS

 

OF

 

THE

 CN2 T

ERMINAL

 

BOARD

1: Power supply 24 VAC-DC
2: Power supply 0V
3: Power supply 12VAC-DC
4: Relay Contact Output
5: Relay Contact Output

I

NITIAL

 F

UNCTIONING

 C

ONDITION

The device makes it possible to activate controls based on the 
light detected through the integrated sensor. Sensor sensitivity 
can be modified using the VR1 trimmer present inside of the 
device.   By   using   the   SEL   and   SET   programming   keys   it   is 
possible  to  select   different  types  of  operation.  In  the  default 
configuration the device is set at an intermediate sensitivity to 
light through the VR1 trimmer and Monostable functioning with 
NO contact output.

A

DJUSTING

 S

ENSITIVITY

 

TO

 

THE

 

CAPTURED

 

LIGHT

The device makes it possible to adjust Sensitivity of the light 
captured through the VR1 trimmer. The switching on of the 
LIGHT LED on the device indicates that the intensity of 
captured light exceeds the selected intervention threshold; in 
this way we will have a reference to the current light conditions 
to establish the desired one.

P

ROGRAMMING

 K

EYS

 

AND

 I

NDICATOR

 LED

SEL Key

: selects the type of function to memorise, the choice 

is indicated by the flashing of the LED. By repeatedly pressing 
the   key,   it   is   possible   to   position   oneself   on   the   desired 
function.   The   selection   remains   active   for   15   seconds, 
displayed   by   the   flashing   LED,   after   which   the   control   unit 
returns to the original status.

SET Key

: carries out programming of the function chosen with 

the SEL key.

Indicator LED

LED on: option memorised.
LED off: option not memorised.
Flashing LED: option selected.

---------------------- MAIN MENU -----------------

LED Reference          LED Off                        LED On

1) MONO                   Monostable                         Impulse 1 sec.
2) TEMP.                    Timer = OFF                        Timer = ON
3) I. CMD                    Relay Output NO                   Relay Output NC

1)

MONO 

(Monostable Operation / Impulse 1 sec.)

The   control   unit   is   supplied   with  the   Monostable   operational 
mode enabled (MONO LED OFF), meaning that the relay will 
activate every time that the sensor determines that there is no 
light, and will deactivate in the presence of light. When needing 
an Impulse type of functioning, meaning that the relay is only 
activated for one second each time that the sensor determines 
that there is no light, programming must be completed in the 
following way:  position the SEL key on the flashing of MONO 
LED   then   press   the   SET   key,   the   MONO   LED   will 
simultaneously switch on permanently and the programming is 
completed.   Repeat   the   procedure   to   restore   the   previous 
configuration.

2)

TEMP. 

(Timer Function enabled / disabled)

The control unit is supplied with the Timer functioning disabled 
(TIMER LED OFF).
When  the  device  needs  to  be  used  with  the  timed  function, 
meaning   that   the  control  relay   is   active   for  the   programmed 
amount of time after the sensor has been activated.
Proceed as follows: position the SEL key on TIMER LED and 
press the SET key to start programming, at the same time the 
TIMER LED will start to double flash; every double flash of the 
TIMER LED corresponds to an increase of 30 minutes up to a 
maximum of 12 hours (24 double flashes), press the SET key 
until the desired time is reached; at the same time the selected 
value is saved and the TIMER LED will stay on.
It is possible  to repeat the operation  in case of an incorrect 
programming.

Displaying the programmed Time

When verifying the previously programmed Time, it is possible 
to  display  it  in  the  following  way:   with  the  SEL key  position 
yourself on TIMER LED, the LED will start to double flash for 
the   number   of   times   equal   to   the   Time   programmed   in   the 
memory (every double flash of the TIMER LED corresponds an 
increase of 30 minutes), (

example: 4 TIMER LED flashes = 120  

minutes).

3)

I. CMD 

( Inversion of NO / NC control functioning )

The   control   unit   is   with   a   Normally   Open   output   operational 
mode (LED I. CMD OFF). 
When needing an inverted mode of operation, with the control 
output set at Normally Closed, proceed as follows: position the 
SEL key on the flashing of LED I. CMD then press the SET 
key, the LED I. CMD will simultaneously switch on permanently 
and the programming is completed. Repeat the procedure to 
restore the previous configuration.

R

ESET

In case it is necessary to reset the device to default factory 
settings,   press   the   SEL   and   SET   keys   together   so   that   all 
indicator LEDs switch on and then immediately off at the same 
time.

1

Rev. 1.0   07/05/2010

GB

Reviews: