Rev. 3.0 13 – 06 - 2016
9
performed. Repeat the operation to restore the previous
configuration.
D) LAMP/CORT (Selecting DS1 operation):
The control unit is supplied by the manufacturer with DS1 = INV
in the closure phase, or rather with the operating mode for
normal photoelectric cells connection enabled (intervention
causes the inversion of the motor during closure).
If you wish to define DS1 = Lock, or rather with the operating
mode for the normal connection of an emergency command
enabled (intervention causes the motor to stop immediately in
both directions), proceed as follows: check that the extended
menu is enabled (T.PAUSA and SEL INPUT 1-2 LEDs start
flashing alternately), use the SEL button to navigate to the
LAMP/CORT LED when it is flashing and press the SET button:
the LAMP/CORT LED lights up and programming is completed.
Repeat the operation to restore the previous configuration.
E) T. MOT (Selecting Input IN3 – IN4 operation):
The control unit is supplied by the manufacturer with inputs IN3
and IN4 = FCAP and FCCH for the normal connection of
opening and closing stop limits.
If you wish to define inputs IN3 and IN4 = DS2 and DS3, or
rather with the operating mode for the normal connection of
photoelectric cells (or other types of safety devices) enabled,
proceed as follows: check that the extended menu is enabled
(the T.PAUSA and SEL INPUT 1-2 LEDs flash alternately),
using the SEL button navigate to T.MOT LED when flashing
and press the SET button: the T.MOT LED lights up and
programming is completed. Repeat the operation to restore the
previous configuration.
RESET:
To restore the default configuration, press the SEL and SET
buttons simultaneously, all
RED
LEDs will light up and then
switch off.
ERROR INDICATION:
-
The control unit enables errors or malfunctions to be identified
using Software tests. If there are errors or malfunctions on the
Input/Output devices, the control unit will indicate the status by
alternately activating and deactivating (for 5 seconds at a time,
and for a maximum period of 1 minute) the 230 V a/c 500 W
output for the connection of the flashing beacon or the courtesy
light.
This guarantees the monitoring of breakdowns in compliance
with Category 2 of EN 954-1. Whenever one of these
malfunctions occurs a qualified professional should be
contacted in order to fix it.
Test Driver Motor:
The control unit is fitted with two drivers used to control the
motor. If there is a malfunction, the control unit will not enable
motion of the shutter and will indicate the test failure visually
through the simultaneous flashing of all LEDs except the T.
MOT LED; which will remain lit in a constant manner. We
recommend that a qualified technician is contacted immediately
in order to resolve the problem. Once the correct operating
conditions are restored the control unit may be switched on
again. The error status is reset and the control unit is ready to
operate normally.
DS1 - DS2 safety device test:
The control unit is designed for connection to safety devices
(see
Notes for the Installer
section) which comply with point
5.1.1.6 of regulation EN 12453. If there is no connection and/or
a malfunction occurs, the control unit does not enable shutter
movement and provides a visual indication of the test failure
through the simultaneous flashing of all LEDs except the INB
CMD PA LED if the cause is the DS1 operating mode, or the
LAMP/CORT LED if the cause is the DS2 operating mode.
After the malfunction has been identified, the control unit makes
it possible to monitor only the opening movements when a user
is present, either using the keypad or the radio control (when
operating via a 2-button radio control the button corresponding
to the closing movement is disabled and when operating via a
3-button radio control the closing movement and Stop buttons
are disabled). We recommend that a qualified technician is
contacted immediately in order to resolve the problem. Once
the correct operating conditions are restored the control unit
may be switched on again. The error status is reset and the
control unit is ready to operate normally.
HARDWARE DIAGNOSTICS:
INPUT IN1 - IN2 - IN3 - IN4 test:
The control unit is fitted with a red LED for every IN 1-2-3-4 low
voltage input so that the status may be monitored immediately.
Operating principle: LED on = input closed, LED off = input
open.