http://www.seav.it
TECHNICAL DATA:
- Power supply
230 Vac 50-60Hz 2000W max.
- Flashing light output : 230 Vac 50Hz
100W Resistive Load max.
50W Inductive Load max.
- Motor outputs
: 230 Vac 50/60 Hz. 750 W max.
- Electric lock output
: 12 Vdc 15 W max.
- Indicator light output
: 24 Vdc 4 W max.
- Power supply to photocells
: 24 Vac 6 W max.
- Safety devices and controls in BT : 24 Vdc
- Operating temperature
: -10
÷
55 °C
- Radio receiver
: see model
- Op. transmitters
: 12-18 Bit or Rolling Code 64-80 bit
-TX max codes in memory : 150 (CODE or PED CODE)
- Board dimensions : 170x145x55 mm.
- Container dimensions
: 240x185x110 mm.
- Protection rating : IP 65
TERMINAL BOARD CONNECTIONS:
CN1 :
1 : Grounding Connection.
2 : Grounding Connection.
3 : Grounding Connection.
CN2 :
1 : 230 Vac line input (Phase).
2 : 230 Vac line input (Neutral)
3 : 230 Vac Flashing light Output (Neutral).
4 : 230 Vac Flashing light Output (Phase).
5 : Motor 1 Output opening 230Vac.
6 : Motor 1 Output common 230Vac.
7 : Motor 1 Output closing 230Vac.
8 : Motor 2 Output opening 230Vac.
9 : Motor 2 Output common 230Vac.
10 : Motor 2 Output closing 230Vac.
CN3 :
1 : Electric lock output 12 Vdc 15 W ( +12V ).
2 : Common lock output – indicator light ( GND ).
3 : 24 Vdc 4 W Indicator light output ( + 24V ).
4 : Photocell control and power supply ( 24Vac 6W ).
5 : Photocell Control and power supply ( GND ).
6 : Open-close push button control PUL input (NA).
7 : Pedestrian push button control PUL PED input (NA).
8 : Common GND input.
9 : BL Blocking Device Input (NC).
10 : Safety device DS1 input (NC).
11 : Safety device DS2 input (NC).
12 : Common GND input.
13 : Motor 1 Opening Limit Switch Input (NC).
14 : Motor 1 Closing Limit Switch Input (NC).
15 : Motor 2 Opening Limit Switch Input (NC).
16 : Motor 2 Closing Limit Switch Input (NC).
17 : Antenna earth input.
18 : Antenna hot pole input.
OPERATING CHARACTERISTICS:
Automatic Operation:
By using both the radio control ( CODE LED on ) and the low
voltage push button panel ( PUL ) to activate the gate, the
following functioning is obtained:
the first impulse commands the opening mechanism until motor
time expires. The second impulse commands gate closing. If an
impulse is sent before the motor time has expired, the control
unit will
reverse
motion direction both for opening and closing.
Step-by-step operation:
By using both the radio control ( CODE LED on ) and the low
voltage push button panel ( PUL ) to activate the gate, the
following functioning is obtained:
the first impulse commands the opening mechanism until the
motor time expires. The second impulse commands gate
closing. If an impulse is sent before the
motor time has expired, the control unit will
stop
the motion
during opening and closing phase. An additional control re-
starts motion in the opposite direction.
Automatic closing :
The control unit closes the gate automatically without sending
additional commands.
Selecting this operating mode is described under the
instructions for setting the pause time.
Pedestrian Passage:
The control unit allows only Motor 1 to be activated using either
the radio control ( CODE PED. LED on) or the push button
panel ( PED ), for the programmed time. ( T.MOT. PED. ).
Blocking Device Input :
The control unit allows the blocking button connection (NC).
Tripping during any operating phase of the control unit causes
movement to stop immediately. An additional movement control
will be valid as long as you have disabled the blocking input,
and, in any case, the unit will carry out the opening stage
automatism with pre-flashing for 5 seconds. If the automation is
fully open, in this case, it will carry out the closing phase.
Warning:
Jumper this input if not used.
Safety device 1 :
The control unit allows Photocells to be powered and connected
in accordance with directive EN 12453.
If the device trips during opening, it is ignored. If it trips during
closing, gate motion is reversed.
The control unit compulsorily requires the use of photocells,
connected to dedicated inputs, otherwise the unit is not enabled
for operation.
Safety device 2:
The control unit allows Photocells to be powered and connected
in accordance with directive EN 12453.
If the device trips during opening, the gate stops momentarily.
Once freed, the control unit continues the opening phase. If the
device trips during closing, gate motion is reversed.
The control unit compulsorily requires the use of photocells,
connected to dedicated inputs, otherwise the unit is not enabled
for operation.
SENSOR 1 ( Operating logic RTX 2278 Sensor 1 ) :
The control unit enables connection of wireless safety devices
in accordance with Directive EN 12453.
The control unit is factory supplied with the following operating
logic installed for Sensor 1 operation: it is not considered if it is
triggered in the opening phase, whereas in the closing phase it
causes a change in direction, if, naturally, module RTX 2278 is
installed on the control unit.
The electronic control unit:
LG 2299 - LRS 2299 - LRS 2299 SET - LRH 2299
LG 2212 New - LRS 2212 New - LRS 2212 New SET
LRH 2212 New
they comply with the specifications of the Directives
RED 2014/53/EU, EMC 2014/30/EU, LVD 2014/35/EU
.
Summary of Contents for LG 2212 New
Page 8: ...Rev 3 3 del 15 12 2020 ...
Page 18: ...Rev 3 3 dated 15 12 2020 ...
Page 28: ...Rév 3 3 du 15 12 2020 ...
Page 39: ...Rev 3 3 vom 15 12 2020 ...
Page 50: ...Rev 3 3 del 15 12 2020 ...
Page 61: ...Rev 3 3 de 15 12 2020 ...
Page 72: ...Αναθ 3 3 της 15 12 2020 ...