background image

Electronic Control Unit LRX 

2215

Electronic control unit for the automation of rolling shutters and 
sun  blinds,  with  optional  Wind  sensor  connection  and 
keypad/radio  control  operation,  for  individual  and  centralised 
control.

- Mod. 

LG 2215 

:                                  Without radio receiver

- Mod.  

LRS 2215 

:

 433,92 MHz

- Mod.  

LRS 2215 SET

:

“Narrow Band” 433.92

MHz

- Mod.  

LRH 2215 

:

“Narrow Band” 868.3

MHz

T

ECHNICAL

 

DATA

- Power supply:

230 V~  50/60 Hz  600 W max.

- Motor output:

230 V~  500 W Max.

- Operating temperature:

-10

55°C

- Radio receiver:

see model

- Compatible radio controls:

12-18 Bit or Rolling Code

- N° of codes which may be stored:                              Max. 6
- N° of Wireless Wind Sensors which may be stored:   Max. 3
- Packaging dimensions:                         110 x 121 x 47 mm.
- Container:                                        ABS  UL94V-0  ( IP54 )

C

ONNECTION

 

OF

 CN1 T

ERMINAL

 

BOARD

1: 230 V line input (Phase).
2: 230 V line input (Neutral).
3: Upward movement motor output.
4: Shared motor output.
5: Downward movement motor output.

C

ONNECTION

 

OF

 CN2 T

ERMINAL

 

BOARD

1: Wind sensor input “W”.
2: T1 local upward movement button input (NA).
3: Shared GND Signal input.
4: T2 local downward movement button input (NA).
5: T3 general upward movement button input (NA).
6: Shared GND Signal input.
7: T4 general downward movement button input (NA).
8: Earth antenna input.
9: Antenna hot pole input.

I

NITIAL

 O

PERATING

 

CONDITION

The equipment can operate using the T1 (Up) and T2 (Down) 
local  command  buttons,  the  T3  (Up)  and  T4  (Down)  general 
command  buttons,  and  in  conjunction  with  one  or  more  radio 
controls.  There  is  no  radio  control  code  stored  in  the  default 
factory setting.

OPERATIONAL DATA:

T1 – T2 Local command buttons operation:

The  following  type  of  operation  is  obtained  by  connecting  the 
local  command  buttons  (normally  open)  for  movement  activa-
tion to the low voltage inputs T1 – T2:
T1 controls upward movement until the motor running time has 
elapsed and T2 controls downward movement. If a command is 
sent  in  the  same  direction  before  the  motor  running  time  has 
elapsed,  the  control  unit  will  stop  movement;  if  a  command  is 
sent in the opposite direction before the motor running time has 
elapsed, the control unit will invert the direction of the motor.

T3 – T4 General command buttons operation:

The  following  type  of  operation  is  obtained  by  connecting  the 
general command buttons (normally open) for movement activ-
ation to the low voltage inputs T3 – T4: 
T3 controls upward movement until the motor running time has 
elapsed and T4 controls downward movement. If a command is 
sent  in  the  same  direction  before  the  motor  running  time  has 
elapsed,  the  control  unit  will  ignore  the  command;  if  a  com-
mand is sent in the opposite direction before the motor running 
time has elapsed, the control unit will invert the direction of the 
motor.

O

PERATION

 

USING

 

DIFFERENT

 M

ODELS

 

OF

 R

ADIO

 C

ONTROL

Different models of radio control may be programmed: by stor-
ing  one  code  (1  button)  a  cyclic  step  by  step  operation  (Up  - 
Stop - Down) is achieved, and by storing two different codes (2 
buttons)  separate  commands  are  created,  one  for  upward 
movement and one for downward movement. Storing a BeFree 
series  radio  control  (3  buttons)  produces  three  separate  com-
mands:  the  first  button  is  used  for  upward  movement,  the 
second for Stop and the third for downward movement.

Operation using a 1-button radio control:

The following type of operation is obtained using a radio control 
with a single button: the first press controls the upward move-
ment  of  the  shutter  until  the  motor  timer  stops.  The  second 
press  controls  the  downward  movement  of  the  shutter.  If  the 
button  is  pressed  before  the  motor  stops  running,  the  control 
unit will stop the shutter moving and the button will need to be 
pressed again to reactivate the motor in the opposite direction.

Operation using a 2-button radio control:

The following type of operation is obtained using a radio control 
with 2 buttons: the first button (“Up”, corresponding to upward 
movement)  controls  upward  movement  until  the  motor  stops 
running  and  the  second  button  (“Down”,  corresponding  to 
downward movement) controls the downward movement of the 
shutter.  If  the  upward  movement  is  interrupted  with  another 
“Up”  command,  the  motor  will  continue  to  run  in  its  upward 
movement  direction.  If,  however,  the  movement  is  interrupted 
with a “Down” command, the control unit will stop the motor.
The procedure remains the same for the downward movement 
phase.

Operation using a 3-button radio control (BeFree x1):

The following type of operation is obtained using the BeFree x1 
radio  control:  the  (Up)  button  controls  upward  movement  until 
the end of the motor running time, the (Stop) button causes all 
movement  to  stop  and  the  (Down)  button  controls  downward 
movement. If a Stop command is sent during upward or down-
ward movement, the control unit causes this movement to stop. 
If  a  command  that  is  in  the  opposite  direction  to  the  current 

1

Rev. 1.1      03/12/10

GB

Summary of Contents for LR 2215 Series

Page 1: ...trols upward movement until the motor running time has elapsed and T4 controls downward movement If a command is sent in the same direction before the motor running time has elapsed the control unit will ignore the command if a com mand is sent in the opposite direction before the motor running time has elapsed the control unit will invert the direction of the motor OPERATION USING DIFFERENT MODEL...

Page 2: ...and Dip 2 ON The User present operating mode can be obtained using the radio control and the keypad i e control must be constantly en abled so that the blind or shutter can be moved as necessary The movement stops when the control is released 4 Venetian blind operation Dip 1 and 2 ON Venetian blind operation can be obtained using the radio con trol and the keypad this involves 2 seconds of User Pr...

Page 3: ...le flash the same number of times as the stored Wind Safety threshold each WIND SPEED LED double flash corresponds to an increase of 5 km h for ex ample 5 WIND SPEED LED flashes 25 km h Wind Safety threshold selection from 5 to 40 km h The sensor is supplied with a default Wind Safety threshold set ting of 25 km h WIND SPEED LED OFF The Wind Safety threshold may be programmed in the following way ...

Page 4: ...complete Repeat the procedure to restore the previous con figuration B SENS CODE Wired Anemometer Test The control unit can be used to check the operation of the con nected Wind sensor and to make sure the rotation direction is correct When installing the device we recommend the blind is placed in an intermediate position so that you can see all con firmation movements during the test procedures A...

Page 5: ... provisions set out by current legislation Compliance with these obligations and the implementation of the minimum safety requirements is the responsibility of the installer We recommend installation is performed in full compliance with EN 60335 2 97 Household electrical appliances and similar Safety part 2 Particular requirements for drives for rolling shutters awnings blinds and similar equipmen...

Reviews: