LRX 2239 ELECTRONIC PANEL

12/24*VDC   low   voltage   electronic   control   unit,   for   the 
automation   of   swinging   and   rolling   gates   with   incorporated 
receiver and battery charger. 

- Mod. 

  LG 2239 

                         : without radio receiver

- Mod.   

LRS 2239 

                       : 433.92 Mhz

- Mod.   

LRS 2239 SET 

                : 433.92 Mhz  “narrow band”

- Mod.   

LRH 2239 

                       : 868.3   Mhz  “narrow band”

TECHNICAL DATA:

- Transformer power supply: 230 Vac  50/60Hz 120W max.
-  Control   unit  power supply:  12  Vac /20*Vac  50/60Hz   120W 
max.
- Flashing light output               

: 12/24* Vdc  4 W max.

- Emergency battery input 

: 12 Vdc  7A/h max.

- Motor outputs                          

: 12/24*Vdc  2 x 50 W max.

- Electric lock output           

: 12/24* Vdc 12W max.

- Power supply to photocells       

: 12/24* Vdc  3 W max. 

- Indicator light output                

: 12 Vdc  3 W max.

- Working temperature          

: -10 - 55 °C

- Radio receiver                       

: refer to type

- Op. transmitters                      

: 12-18 Bit or Rolling Code

- TX max codes in memory           : 120 (CODE or CODE PED)
- Dimensions of container            

: 240x190x110 mm.

- Protection degree                 

: IP 56

* If using 24Vdc motors, replace the transformer provided  
with a 230/20 Vac transformer the power of which is suited  
to the type of motor used (120W max; the outputs for the  
flashing light, electric lock and photocell power supply will  
adapt to the voltage of 24Vdc, but it is only ever possible  
to   connect   a   12Vdc   battery,   even   when   using   24Vdc  
motors).

TERMINAL BOARD CONNECTIONS:

CN1 :

1   : Power supply input 12 / 20* Vac 120W max.
2   : Power supply input 12 / 20* Vac 120W max..
3   : Input + Emergency battery 12Vdc 1.2 / 7 Ah max.
4   : Input – Emergency battery 12Vdc 1,2 / 7 Ah max.
5   : Input + Solar panel
6   :  Flashing light 12/24*Vdc 4W max.
7   : Output - Flashing light 12/24*Vdc 4W max.
8   :  Motor 1.
9   : Output - Motor 1.
10 :  Motor 2.
11 : Output - Motor 2.

CN2 :

1  : Electric lock Output (+ 12/24*Vdc  12W).
2  : Electric lock Output (+ 12/24*Vdc  12W).
3  : Control and power supply to photocells (+ 12/24*Vdc  3W ).
4  : Control and power supply to photocells (+ 12/24*Vdc  3W ).
5  : Indicator light output (+ 12Vdc  3W  ).
6  : Indicator light output (- 12Vdc  3W  ).
7  : Open-Close/Open push button input (NO).
8  : Pedestrian / Close push button input (NO),  DS AUX (NC).
9  : Common GND input.
10: Block input (NC).
11: Safety device input (NC).
12: Opening limit switch input for motor 1 (NC).
13: Closing limit switch input for motor 1 (NC).
14: Common GND input.
15: Opening limit switch input for motor 2 (NC).
16: Closing limit switch input for motor 2 (NC).
17: Aerial earth input.
18: Aerial hot pole input.

OPERATING CHARACTERISTICS:

Automatic:

Using either the radio control (CODE led lit) or the low tension 
button panel (PUL) to operate the gates, commands will have 
the  following  effect:  the  first  command  impulse   activates  the 
opening   mechanism   either   for   the   pre-set   motor   operating 
interval or until the activation of the opening limit switch. The 
second   command   impulse   closes   the   gate.   If   a   command 
impulse is received before the activation of the limit switch the 
direction   of   movement   of   the   mechanism   will   be   reversed 
whether engaged in opening or closing operations.

Step-by-step:

Using either the radio control (CODE led lit) or the low tension 
button panel (PUL) to operate the gates, commands will have 
the  following  effect:  the  first  command  impulse   activates  the 
opening   mechanism   either   for   the   pre-set   motor   operating 
interval or until the activation of the opening limit switch. The 
second   command   impulse   closes   the   gate.   If   a   command 
impulse is received before the activation of the limit switch the 
movement   of   the   mechanism   will   be   stopped.   A   further 
command   impulse   will   reactivate   the   mechanism   in   the 
opposite direction.

Automatic closing:

The mechanism may be set up to automatically close the gate 
without sending additional commands.
The set-up procedure is described in the instructions for setting 
the delay period.

Pedestrian access:

Using the radio command (the CODE PED.  led is on) or the 
button   panel   (PED),   you   can   activate   just   motor   1   for   the 
programmed length of time (T.MOT.PED. led). 

Block input:

The control board allows for the connection of a blocking button 
(NC).   Commands   from   the   button   during   any   phase   will 
immediately stop the movement of the gate. A further command 
will only be executed if the blocking mechanism is deactivated, 
and in any case normal automatic opening will work.
If not used the terminals must be jumped.

Safety device:

The   control   board   allows   for   the   connection   and   control   of 
photocells in accordance with directive EN 12453.
Commands from the device during  the opening phase will be 
ignored,   and   when   the   gate   is   closing   they   will   reverse   the 
direction of movement.
The control board needs the photocells to be connected to their 
respective dedicated inputs, otherwise it will not work.

AUX 1 safety device (PED input):

The   control   unit,   when   configured,   can   be   fitted   with   an 
Auxiliary   1   safety   device  together   with   the   Pedestrian   Input 
(NC).
Commands from the device during the opening phase will stop 
the   gate   temporarily;   when   reactivated,   the   control   unit 
continues   the   opening   phase.   Commands   whilst   the   gate   is 
closing will reverse the direction of movement.

AUX 2 safety device (PED input):

The   control   unit,   when   configured,   can   be   fitted   with   an 
Auxiliary   2   safety   device   together   with   the   Pedestrian   Input 
(NC).
Commands from the device during an opening or closing phase 
temporarily reverse and then stop the movement.

Opening and closing limit switch:

The   control   unit   permits   the   connection   of   an   Opening   and 
Closing limit switch for each Motor (NC). Commands from the 
limit   switches   during   the   respective   work   phases   stop   the 
respective motors immediately.

Warning:   Connect   the   limit   switches,   if   available;  
otherwise do not jump the FA1, FC1, FA2 or FC2 inputs  
on the terminal board. 

                                                                                            1                                                      Rev. 1.0    08/10/2010

GB

Summary of Contents for LRS 2239

Page 1: ...ommand impulse is received before the activation of the limit switch the direction of movement of the mechanism will be reversed whether engaged in opening or closing operations Step by step Using either the radio control CODE led lit or the low tension button panel PUL to operate the gates commands will have the following effect the first command impulse activates the opening mechanism either for...

Page 2: ... key selects the type of function to be stored selection is indicated by a flashing LED By pressing the key repeatedly you can select the desired function The selection remains active for 10 seconds indicated by the flashing LED after 10 seconds the control unit returns to its original status SET key programmes the information according to the type of function selected previously using the SEL key...

Page 3: ... key to the RIT ANTE LED when flashing press the SET key wait for the desired interval of time then press the SET key again the fixed door delay time of 2 seconds during opening is stored the door delay time during closing is stored for the programmed time and the RIT ANTE LED is on To restore the initial configuration without door delay go to the RIT ANTE LED when flashing then press the SET key ...

Page 4: ...f the transmission code not enabled to enable the function proceed as follows check the extended menu 2 is enabled the T PAUSA and RIT ANTE LEDs flash simultaneously press the SEL button until the TIPO MOTOR LED flashes then press the SET key at the same time the LED TIPO MOTOR turns on and remains steady and programming is complete Repeat the operation to restore the previous configuration B AUTO...

Page 5: ... the TIPO MOTORE AUTO PGM and CODE LEDs are steady while the CODE PED Led flashes press SET to confirm The default setting is Level 3 RESET To restore the default configuration press the SEL and SET keys simultaneously all RED LEDs will light up and then switch off DIAGNOSTICS Photocell test The control unit can be fitted with safety devices in accordance with step 5 1 1 6 of the EN 12453 standard...

Page 6: ...back of the casing is set up for mounting on a wall holes for mounting with nogs or holes for screws Take all precautions to ensure the IP degree of protection is not affected during installation If applicable the keypad for manual control must be mounted in such a way as not to compromise the safety of the user The motor reducer used to move the shutter must comply with section 5 2 7 of EN 12453 ...

Page 7: ...7 Rev 1 0 08 10 2010 ...

Reviews: