Before shutter automation, it is necessary to check  

the   product   is   in   good   condition   and   that   it  

complies   with   EN   12604   and   the   Machines  
Directive.

 

The control unit is not equipped with a 230 V a/c  

electric   line   sectioning   device.   The   installer   is  
responsible for installing a sectioning device in the 

system.

  The sectioning device must be positioned so  

that   it   is   protected   against   accidental   closure,   in  
compliance with section 5.2.9 of standard EN 12453. 

The wiring of external electrical components must  

comply with EN  60204-1 as amended in section  

5.2.7   of   EN   12453.   Power   supply   leads   and 
connection   cables   must   be   secured   through   the  

use of cable clamps, which are supplied with the 
product.

 

Take care when drilling the outer casing to feed through  

the power and connecting cables and when assembling  
the   cable   glands,   to   maintain   the   IP   degree   of  
protection of the casing as best as possible. Also take  
care to fasten the cables firmly in place.

The back of the casing is set up for mounting on a wall  

(holes   for   mounting   with   nogs,   or   holes   for   screws).  
Take   all   precautions   to   ensure   the   IP   degree   of 
protection is not affected during installation.   

If   applicable,   the   keypad   for   manual   control   must   be  

mounted in such a way as not to compromise the safety  
of the user.

The motor reducer used to move the shutter must  

comply with section 5.2.7. of EN 12453.

 

The   D.S.   Power   Supply   output   is   specifically   for  

powering the photocells.  It must not be used  for any  
other applications.

The control unit tests the working order of the photocells  

for   each   work   cycle   to   guarantee   the   safety   of   the  
Category   2   anti-crushing   devices   in   accordance   with  
step 5.1.1.6 of EN 12453. The control unit is disabled  
whenever the safety devices are not connected and/or  
not in good working order.

For the radio receiver to operate correctly when two or  

more control units are used, we recommend that you  
install the devices  at least  3 metres  away  from each  
other.

   

SEAV s.r.l.

 declares that the product:

Electronic panel:

LG 2239 - LRS 2239 - LRS 2239 SET - LRH 2239

Complies with the requirements of Directives 

R&TTE 99/5/EC, EMC 2004/108/EC, LVD 2006/95/EC

.

                                                                                            6                                                      Rev. 1.0    08/10/2010

Summary of Contents for LRS 2239

Page 1: ...ommand impulse is received before the activation of the limit switch the direction of movement of the mechanism will be reversed whether engaged in opening or closing operations Step by step Using either the radio control CODE led lit or the low tension button panel PUL to operate the gates commands will have the following effect the first command impulse activates the opening mechanism either for...

Page 2: ... key selects the type of function to be stored selection is indicated by a flashing LED By pressing the key repeatedly you can select the desired function The selection remains active for 10 seconds indicated by the flashing LED after 10 seconds the control unit returns to its original status SET key programmes the information according to the type of function selected previously using the SEL key...

Page 3: ... key to the RIT ANTE LED when flashing press the SET key wait for the desired interval of time then press the SET key again the fixed door delay time of 2 seconds during opening is stored the door delay time during closing is stored for the programmed time and the RIT ANTE LED is on To restore the initial configuration without door delay go to the RIT ANTE LED when flashing then press the SET key ...

Page 4: ...f the transmission code not enabled to enable the function proceed as follows check the extended menu 2 is enabled the T PAUSA and RIT ANTE LEDs flash simultaneously press the SEL button until the TIPO MOTOR LED flashes then press the SET key at the same time the LED TIPO MOTOR turns on and remains steady and programming is complete Repeat the operation to restore the previous configuration B AUTO...

Page 5: ... the TIPO MOTORE AUTO PGM and CODE LEDs are steady while the CODE PED Led flashes press SET to confirm The default setting is Level 3 RESET To restore the default configuration press the SEL and SET keys simultaneously all RED LEDs will light up and then switch off DIAGNOSTICS Photocell test The control unit can be fitted with safety devices in accordance with step 5 1 1 6 of the EN 12453 standard...

Page 6: ...back of the casing is set up for mounting on a wall holes for mounting with nogs or holes for screws Take all precautions to ensure the IP degree of protection is not affected during installation If applicable the keypad for manual control must be mounted in such a way as not to compromise the safety of the user The motor reducer used to move the shutter must comply with section 5 2 7 of EN 12453 ...

Page 7: ...7 Rev 1 0 08 10 2010 ...

Reviews: