background image

RXX 2167  230V

M

ULTICHANNEL

 M

ODULAR

 R

ECEIVER

The   radio   receiver   RXX   2167   230V,   allows   the   remote   control   of 

electric   and   electronic   devices   when   coupled   with   one   or   more 

transmitters. The receiver is adapted with two serial channels and has 

the capacity of maximum 4 channels.
­ Mod. 

RXQ 2167  230V *

:

30,875

MHz

­ Mod. 

RX 2167  230V*

:

306

MHz

­ Mod. 

RX 2167/330  230V*

:

330

MHz

­ Mod. 

RXS 2167  230V

:

433,92

MHz

­ Mod. 

RES 2167  230V

: Narrow band

433,92

MHz

­ Mod. 

RXH 2167  230V

: Narrow band

868,3

MHz

*This product is destined for countries in which use is consented.

T

ECHNICAL

 

DATA

:

­ Power supply

230V~  4,5W

­ Work frequency

see model

­ Optional transmitter

 12­18 bit or Rolling code

­ TX codes memorable per channel                                        60 Max

­ Channels

­2 to a maximum of 4

­ Optional additional channel .:

ML 2168

­ Command relay:

30VDC 1A open

­ Working temperature:

­20÷55°C

­ Dimensions:

110x121x47mm

­ Rating in open space:

50­100 metres

­ Container:

ABS V­0

­ Protection level:

IP54

I

NSTALLATION

 

OF

 

THE

 R

ECEIVER

:

It is very important to choose the place of installation carefully in order 

to  obtain  an  optimal  functioning   between     the  transmitter  and  the 

receiver.   Capacity   is   not   only   conditioned   by   the   technical 

characteristics of the device, but also varies according to the radio­

electric conditions of the site.

The receiver is adapted with a machined antenna with a rigid crop 

ended wire, if you want to increase the sensibility it is possible to 
connect a tuned antenna  

(H868 = 868MHz, H433 = 433MHz, H7 = 

306­330MHz,   H30   =   30,875MHz)

  coaxial   median   cable   RG58   50 

Ohm.

The antenna should be visually positioned on the exterior and far from 

metal   structures.   There   must   be   a   distance   of   at   least   5   metres 

between the two receivers if installation is to be successful.

M

ODALITY

 

OF

 

OPERATION

It is possible to choose the following modalities of operation through 

the Switch selecting SW1­SW2 respectively for the first and second 

channel.

Monostable

Time. 60s

Time. 30s

Bistable

P

ROGRAMMING

:

The radio­controls programming to be used is of a self­learning kind, 

and can be carried out as follows:

Press the SEL button, as a result of which the Led CODE will begin to 

flash. Send the selected code using the radio­control, making sure 

that you stand a few metres away. When the Led remains illuminated, 

programming is finished.

For   the   programming   of   the   second   channel   follow   the   same 

procedures though press SEL twice.

It is possible  to repeat  the memorisation  procedure using up to a 

maximum of 60 codes. By continuing to repeat the operation once the 

available memory capacity is used up, the Led code will start to flash 

rapidly, indicating that further storage is not possible.

For   the   programming   of   the   modules   ML   2168   follow   the   same 

procedures mentioned above, using the respective tasks.

A

BILITY

 

OF

 

PROGRAMMING

 

THROUGH

 R

ADIO

 

CONTROL

 :

Ability of programming through Radio command.

The   panel   is   furnished   by   the   builder   with   the   radio   command 

disabled, if you wish to enable the function, proceed in the following 

manner: the panel board is powered by an output of 230Vac, keeping 

the   SELL   task   pressed,   at   the   same   time   you   will   obtain   a   brief 

flashing of all the Leeds and the programming will be complete. 

If you wish to disable the function previously enabled, repeat the 

operation or follow the RESET procedure. 

P

ROGRAMMING

 

USING

 

THE

 

RADIO

 

CONTROL

:

This procedure makes it possible to programme the device without 

touching   the   SEL   buttons   on   the   receiver,   but   to   carry   out   the 

operation from a distance.

The procedure is carried out in the following way:

transmit the previously memorised radio control code for just over 10 

seconds, in an uninterrupted way. At the same time, the main device 

goes into a programming mode. From a few metres away from the 

main device, transmit the selected code using the radio control. The 

programming will then be complete.

“The   central   enters   into   programming   mode   through   the 

corresponding channel previously memorised by the radio control.”

R

ESET

:

If you wish to reset the receiver to its original configuration, (without 

any memorised code), press the RESET button and at the same time 

Led will switch off, the same for models ML 2168.

MODULE

 

OF

 C

HANNEL

 ML 2168

The same modality of programming and operation is used for added 

modules  ML 2168.