RXX 2167 230V
M
ULTICHANNEL
M
ODULAR
R
ECEIVER
The radio receiver RXX 2167 230V, allows the remote control of
electric and electronic devices when coupled with one or more
transmitters. The receiver is adapted with two serial channels and has
the capacity of maximum 4 channels.
Mod.
RXQ 2167 230V *
:
30,875
MHz
Mod.
RX 2167 230V*
:
306
MHz
Mod.
RX 2167/330 230V*
:
330
MHz
Mod.
RXS 2167 230V
:
433,92
MHz
Mod.
RES 2167 230V
: Narrow band
433,92
MHz
Mod.
RXH 2167 230V
: Narrow band
868,3
MHz
*This product is destined for countries in which use is consented.
T
ECHNICAL
DATA
:
Power supply
230V~ 4,5W
Work frequency
see model
Optional transmitter
1218 bit or Rolling code
TX codes memorable per channel 60 Max
Channels
2 to a maximum of 4
Optional additional channel .:
ML 2168
Command relay:
30VDC 1A open
Working temperature:
20÷55°C
Dimensions:
110x121x47mm
Rating in open space:
50100 metres
Container:
ABS V0
Protection level:
IP54
I
NSTALLATION
OF
THE
R
ECEIVER
:
It is very important to choose the place of installation carefully in order
to obtain an optimal functioning between the transmitter and the
receiver. Capacity is not only conditioned by the technical
characteristics of the device, but also varies according to the radio
electric conditions of the site.
The receiver is adapted with a machined antenna with a rigid crop
ended wire, if you want to increase the sensibility it is possible to
connect a tuned antenna
(H868 = 868MHz, H433 = 433MHz, H7 =
306330MHz, H30 = 30,875MHz)
coaxial median cable RG58 50
Ohm.
The antenna should be visually positioned on the exterior and far from
metal structures. There must be a distance of at least 5 metres
between the two receivers if installation is to be successful.
M
ODALITY
OF
OPERATION
It is possible to choose the following modalities of operation through
the Switch selecting SW1SW2 respectively for the first and second
channel.
T
Monostable
Time. 60s
Time. 30s
Bistable
P
ROGRAMMING
:
The radiocontrols programming to be used is of a selflearning kind,
and can be carried out as follows:
Press the SEL button, as a result of which the Led CODE will begin to
flash. Send the selected code using the radiocontrol, making sure
that you stand a few metres away. When the Led remains illuminated,
programming is finished.
For the programming of the second channel follow the same
procedures though press SEL twice.
It is possible to repeat the memorisation procedure using up to a
maximum of 60 codes. By continuing to repeat the operation once the
available memory capacity is used up, the Led code will start to flash
rapidly, indicating that further storage is not possible.
For the programming of the modules ML 2168 follow the same
procedures mentioned above, using the respective tasks.
A
BILITY
OF
PROGRAMMING
THROUGH
R
ADIO
CONTROL
:
Ability of programming through Radio command.
The panel is furnished by the builder with the radio command
disabled, if you wish to enable the function, proceed in the following
manner: the panel board is powered by an output of 230Vac, keeping
the SELL task pressed, at the same time you will obtain a brief
flashing of all the Leeds and the programming will be complete.
If you wish to disable the function previously enabled, repeat the
operation or follow the RESET procedure.
P
ROGRAMMING
USING
THE
RADIO
CONTROL
:
This procedure makes it possible to programme the device without
touching the SEL buttons on the receiver, but to carry out the
operation from a distance.
The procedure is carried out in the following way:
transmit the previously memorised radio control code for just over 10
seconds, in an uninterrupted way. At the same time, the main device
goes into a programming mode. From a few metres away from the
main device, transmit the selected code using the radio control. The
programming will then be complete.
“The central enters into programming mode through the
corresponding channel previously memorised by the radio control.”
R
ESET
:
If you wish to reset the receiver to its original configuration, (without
any memorised code), press the RESET button and at the same time
Led will switch off, the same for models ML 2168.
MODULE
OF
C
HANNEL
ML 2168
The same modality of programming and operation is used for added
modules ML 2168.
Module for Additional Channel ML 2168
Rev 1.3 04/07
GB