LEAK CHECK & LEAK DOWN TEST
Check all connections for gas leaks with a non-corrosive and non-toxic leak
detection fluid.
Ammonia, which is present in some soaps and detergents, attacks brass fittings.
Undetectable at first, in a matter of months these fittings may develop cracks and
leaks.
WARNING
DO NOT USE OPEN FLAME TO CHECK FITTINGS AND GAS LINES FOR LEAKS.
Checking for leaks with an open flame may result in a fire or explosion.
TO LIGHT THE BURNERS
1.
Push down the knob and turn counterclockwise to “IGNITE” position.
2. Hold the knob down fully until the spark ignites the gas and continue to
hold the knob down for approximately 5 to 10 seconds. The
thermocouple will be heated to activate the safety mechanism.
3. Release the knob and set to desired setting.
4. To turn off the burner flame, turn the knob clockwise to “OFF” position.