Frequently used menus
17
2.4
Correlation menu (Offline correlation)
In Offline measurement mode with Multi sensors, the Correlation menu differs in the
following aspects from the menu in Online measurement mode.
Element Description
Number of correlated audio blocks
The displayed curve is the result of an averaging from up to 10 single
correlations.
Number of the sensor at the measuring point
Pipeline between the measuring points
The graphic illustrates the pipeline between the measuring points.
Tap to open the Pipe data menu.
Pipeline sections
Installation points of
sensors No.3 and 4