Step Description
5
To start the measurement, tap the large central button in the display area or
tap the button
in the main menu.
Result:
The correlation starts. The Correlation Analysis menu opens.
Rate the correlations. To do so answer the following questions.
Is the radio signal of both transmitters strong enough?
If the radio symbol
shows a strong signal, the measurement can be
continued and a detailed analysis can be started.
If the radio symbol
shows a weak signal, a continuous correlation will
be hardly or not possible.
The following actions may help:
•
Move closer to the Power transmitter in question.
•
Place the transmitter higher
(e.g. on a wall or on a traffic cone or similar).
•
If necessary, place the transmitter at an other measuring point.
•
If possible, there should be a direct line of sight connection between
Correlator and transmitter.
If still no connection can be made, conduct an Offline measurement instead
of the Online measurement.
Is the correlation result reliable?
The curve shows one clear peak;
the lag value
is green or yellow
and does not fluctuate
The curve shows no clear peak;
the lag value
is red and fluctuating
Meaning: The result is reasonable.
How to proceed: Continue the
measurement and start a detailed
analysis.
How to proceed: If you still suppose a leak to be
here, the following can help:
•
Access the system settings menu, adjust the
„Averaging“ to “unlimited” and restart the
correlation.
•
Conduct an Offline measurement (at night)
instead of the Online measurement.
Rate the correlation
Summary of Contents for Correlux C-3
Page 2: ...Consultation with SebaKMT 2 ...
Page 8: ...Terms of Warranty 8 ...
Page 14: ...Frequently used menus 14 ...
Page 18: ...Frequently used menus 18 ...
Page 20: ...Frequently used menus 20 ...
Page 22: ...Frequently used menus 22 ...
Page 24: ...Frequently used menus 24 ...
Page 26: ...Frequently used menus 26 ...
Page 40: ...The Multi sensors 40 ...
Page 60: ...Sensor management 60 ...
Page 68: ...Online correlation 68 ...
Page 76: ...Offline correlation Multipoint measurement 76 ...
Page 84: ...Real time measurement 84 ...
Page 92: ...Sound velocity measurement 92 ...
Page 100: ...Storage Management of correlations History 100 ...
Page 102: ...Reset of correlation settings and data 102 ...
Page 110: ...Pinpointing 110 ...
Page 120: ...Firmware update 120 ...