Use the following questions to assess whether the leak position seems plausible or not.
Is one of the values
zero or close to zero?
If the answer is
NO
, the values seem plausible.
Continue the measurement and start a detailed analysis.
If the answer is
YES
, the leak is located precisely at the measuring point or outside the
correlated pipe section.
Cancel the measurement. Take the relevant transmitter and look for a new installation
point in order to enlarge the measuring length. Then start a new correlation.
Does each value
show the half of the measuring length
If the answer is
NO
, the values seem plausible.
Continue the measurement and start a detailed analysis.
If the answer is
YES
, the leak is located precisely half way between the measuring
points or a measuring error has occurred (so called ‘center point correlation’).
Cancel the measurement. Take one of the transmitters and look for a new installation
point in order to enlarge the measuring length. Then start a new correlation.
Use the various tools to analyze the displayed correlation:
•
When you tap the displayed correlation curve, the
Correlation analysis menu
with
the relevant tools opens.
•
When you tap the displayed coherence curve, the
Frequency analysis menu
with
the relevant tools opens.
Use the Back button
to return to the Correlation menu.
Some settings for calculating and presenting the correlation curve can be changed in
the in the System settings menu (see page 51).
Rate the leak position
Detailed analysis
Summary of Contents for Correlux C-3
Page 2: ...Consultation with SebaKMT 2 ...
Page 8: ...Terms of Warranty 8 ...
Page 14: ...Frequently used menus 14 ...
Page 18: ...Frequently used menus 18 ...
Page 20: ...Frequently used menus 20 ...
Page 22: ...Frequently used menus 22 ...
Page 24: ...Frequently used menus 24 ...
Page 26: ...Frequently used menus 26 ...
Page 40: ...The Multi sensors 40 ...
Page 60: ...Sensor management 60 ...
Page 68: ...Online correlation 68 ...
Page 76: ...Offline correlation Multipoint measurement 76 ...
Page 84: ...Real time measurement 84 ...
Page 92: ...Sound velocity measurement 92 ...
Page 100: ...Storage Management of correlations History 100 ...
Page 102: ...Reset of correlation settings and data 102 ...
Page 110: ...Pinpointing 110 ...
Page 120: ...Firmware update 120 ...