Offline correlation (Multipoint measurement)
71
Step Description
9
Deploy the sensors at the measuring
points.
Deploy the sensors at the measuring
points.
Result:
Once the countdown reached
zero, the sensors start measuring.
A new countdown of 2min 30sec is
displayed on the Correlator screen
representing the total time of the
measurement. During this time, the
sensors simultaneously record 10 audio
blocks, each of 3 seconds length. Once
the countdown reached zero, the
measurement is completed.
Result:
The sensors start measuring at
the programmed time.
A new countdown is displayed on the
Correlator screen showing the time
remaining until the programmed end of
measurement.
During this time, the sensors
simultaneously record 10 audio blocks,
each of 3 seconds length. Once the
countdown reached zero, the
measurement is completed.
10
Once the measurement is completed, collect the sensors.
The sensors need to remain turned on. Otherwise the measurement data would
be lost.
To read the measuring data from the sensors, proceed as follows:
Step Description
1
In the Start menu, select the required Offline measuring mode.
2
In the displayed menu, tap the
Read
button.
Result:
The Correlator successively contacts all sensors. Thereby, the devices
are synchronized. Then, the following menu appears:
(continued on next page)
Deploying sensors
Reading out data
Summary of Contents for Correlux C-3
Page 2: ...Consultation with SebaKMT 2 ...
Page 8: ...Terms of Warranty 8 ...
Page 14: ...Frequently used menus 14 ...
Page 18: ...Frequently used menus 18 ...
Page 20: ...Frequently used menus 20 ...
Page 22: ...Frequently used menus 22 ...
Page 24: ...Frequently used menus 24 ...
Page 26: ...Frequently used menus 26 ...
Page 40: ...The Multi sensors 40 ...
Page 60: ...Sensor management 60 ...
Page 68: ...Online correlation 68 ...
Page 76: ...Offline correlation Multipoint measurement 76 ...
Page 84: ...Real time measurement 84 ...
Page 92: ...Sound velocity measurement 92 ...
Page 100: ...Storage Management of correlations History 100 ...
Page 102: ...Reset of correlation settings and data 102 ...
Page 110: ...Pinpointing 110 ...
Page 120: ...Firmware update 120 ...