5-50
5.4.7.2 Testing FTP Data Transfer
Perform the following steps to check the FTP settings:
Step
Action
Click on the Test GSM settings button.
1
Result: A new window appears.
Click on the Send Test FTP data button. Thereupon, the logger tries to
create a test file inside the respective folder on the FTP server. During
the test procedure, the I/O control lamp
is lit orange.
2
Result: If a file has been created in the folder, the test was successful.
3
If no file has been created, the logger probably failed to establish a GSM
connection or was not able to establish a connection to the server. Click
on the Read GSM log button in order to identify possible sources of the
problem (see step 3 of previous section). Do also check the FTP
settings.
5.4.8
Finishing the Communication Setup
Close and save the communication settings by clicking on the Save button.
5.5
Start Time
The point in time, the logger starts logging, has to be defined under Record.
You can specify a point in time using the controls. If you click on the Start with next
Configuration send button, logging starts right after the configuration has been
transmitted to the logger.