2.2  Rooms where no smoke alarm detector should be installed 

 

 

Rooms which have a high air humidity - for example in the bathroom. 

 

In garages or kitchens. A smoke alarm detector in the kitchen should only be installed, if the 

distance to the stove is at least 4m. 

 

Smoke alarm detectors should not be installed close to heaters, heating-, cooling- and 

ventilation-shafts. Also, they may not be mounted on open fires or fireplaces. 

 

In very dusty rooms. 

 

With A-shaped roofs the smoke alarm detectors may not be mounted at the highest point. 

 

Rooms having a room temperature of below 5°C or above 45°C. 

 

In caravan or similar rooms. In these living areas, the attachment to the inside of parts are 

advised. The air in the upper part of these areas as well as the ceiling is strongly warmed up 
by intense solar irradiation. This can result that the strongly warmed up air keeps the smoke 
from reaching to the smoke alarm detector. 

 

3.  Installation 

 

Before starting up this product, please check for external damage. In case of visible external 
damage we immediately dis-advise the start-up of this product! Please remove all packaging 
material of this product before the first start-up. 

 

Disconnect the mounting base by turning it counterclockwise from the case. 

The mounting base can be mounted using the included screws on the ceiling (

see Figure 4

). 

 

 

 

 

 

 

 

 

 

 

Figure 4: 

Overview of the mounting base for mounting with screws

 

 

 

Summary of Contents for GS506G

Page 1: ...no smoke alarm detector should be installed 5 3 Installation 5 4 Startup 6 4 1 Activation and function control of the smoke alarm detector 6 4 2 Recurrent self test of the smoke alarm detector on its function 7 5 Technical Data 7 6 Replacing batteries 7 7 Reasons for triggering a false alarm 8 8 Behavior in case of fire 9 9 Notes to the use of batteries 9 10 Maintenance and cleaning 9 11 Disposal ...

Page 2: ...t a loud alarm will sound The smoke alarm detector identifies the smoke and not the flame of a fire This smoke alarm detector type GS506G may only be used in private rooms After a maximum of 10 years as well as with signaling the battery fault signal the smoke alarm detector must be replaced Before mounting the smoke alarm detector the product must be activated see section 4 1 The smoke alarm dete...

Page 3: ...st humidity and moisture splashing or dripping Damaged smoke alarm detectors must be replaced immediately 2 Mounting location in rooms of the smoke alarm detectors 2 1 Smoke alarm detectors should be installed in the following rooms Bedrooms If several bedrooms are in the house then the attachment of smoke alarm detectors in each bedroom are advised Corridors and stairways Because stairwells easil...

Page 4: ...ounted away from the corner of the room see Figure 3 Figure 3 Mounting the smoke alarm detector on the ceiling On ceiling beams which are thicker than 20 cm no installation of smoke alarm detector should be done A minimum distance of 50 cm is urgently recommended The smoke alarm detector should be mounted at least 50 cm away from lamps and fluorescent lamps An installation height of 6m maximum sho...

Page 5: ...avan or similar rooms In these living areas the attachment to the inside of parts are advised The air in the upper part of these areas as well as the ceiling is strongly warmed up by intense solar irradiation This can result that the strongly warmed up air keeps the smoke from reaching to the smoke alarm detector 3 Installation Before starting up this product please check for external damage In ca...

Page 6: ...detector The SET button is used to check the function of the smoke alarm detector After pressing the key a very loud alarm will sound Keep the smoke alarm detector at least an arm s length away from your body while pressing the SET button The activation of the alarm takes place after approximately 4 seconds of pressing the SET button Afterwards the LED starts flashing and the alarm sounds In this ...

Page 7: ...ged Additionally the LED flashes The smoke alarm detector is still fully functional at this time However it is recommended to replace the battery as soon as the smoke alarm detector is warning about the empty state of the battery Please always replace the battery with an identical battery type which is having the same technical specifications as the used battery lithium battery ER9V Never use batt...

Page 8: ...ery has been inserted incorrectly please note and pole Note Please check the smoke alarm detector after replacing the battery always on its function 7 Reasons for triggering a false alarm The following may be causes of a false alarm Water and kitchen steam high air humidity dust Strong drafts etc Usually the smoke of cigarettes does not trigger the alarm If the alarm still be triggered please make...

Page 9: ...duction of smoke please keep close to the ground and breathe if possibly through a cloth Better still by a damp cloth You may enter the house again only after release or permission of the fire brigade 9 Notes to the use of batteries 1 Non rechargeable batteries are not to be re charged 2 New batteries should not be used together with used batteries Please always use batteries with the same type 3 ...

Page 10: ...are marked with the symbol of a crossed out waste bin and may not be disposed of with household waste Under the dustbin symbol is the chemical name of the harmful substance in the example below CD for cadmium Pb stands for lead HG for mercury Meaning of symbols 1 Battery containing more than 0 002 mass percent of cadmium 2 Battery containing more than 0 0005 mass percent of mercury 3 Battery conta...

Page 11: ...11 The declaration of performance for this product can be found under the following link www sebson de DOP_GS506_EN pdf SEBSON Sebastian Sonntag Gernotstr 17 44319 Dortmund Germany www sebson de ...

Reviews: