Trouble shooting
UR46-81/82S
Document number: SG104148TEN
Revision: B01
Issue date: 20.8.2012
Copyright© 2012 Sécheron SA - This document is not contractual and contains information corresponding to the level of technology at the date of release.
E-48
File: e-UR46-8S_trouble_en.fm
Procedure 3: adjusting the rated gap
a) Remove the four screws (5) and remove the cover (2).
b) Rotate the flange (9) until the following E dimensions are obtained:
– E = 10
±0.1
mm for type E (electric hold)
– E = 8.5
±0.1
mm for type M (magnetic hold)
c) Mark the new point (10) corresponding to the rated gap on the body (4).
d) Insert the cover (2) and tighten the four screws (5) to a torque of 9 Nm.
e) Mark the cover (2), with a extension of the marking (10) on the body (4) to indicate the posi-
tion of the flange (9).
03643
E.3
Performance check
See the trouble shooting sheets for M or E type if one of the functions is not carried out during the
test.
a) Close the circuit-breaker and check:
– the closing current;
– the holding current (E type).
b) Trip the circuit-breaker by giving it an “Off” order and check:
– the tripping current (M type).
c) Close the circuit-breaker, disengage the fork (1) from the catches (2), give an “Off” order to
the closing device (3) and check:
– the return of the fork (1) to the rest position.
04644-S
Important!
Do not turn the flange (9) after this adjustment.