background image

 

 

 

Double-Door Electromagnetic Locks 

Installation Manual 

E-941DA-1K2Q shown 

 

Model 

Holding Force

 

Material 

E-941DA-600Q 

600-lb. (272kg) x2 

Anodized aluminum 

E-941DA-1K2Q 

1200-lb. (545kg) x2 

Anodized aluminum 

E-941DA-600PQ* 

600-lb. (272kg) x2 

Anodized aluminum 

E-941DA-1K2P* 

1200-lb. (545kg) x2 

Anodized aluminum 

*

With status LED and bond sensor 

       

Holding force has not been verified by UL 

 

MOV surge protection  

 

Adjustable mounting bracket  

 

Complete mounting hardware for typical installations 

 

"

L" bracket and "Z" brackets available for easy mounting   

 

Detachable faceplate 

 

12/24VDC selectable  

NOTES 

 

UL294 Indoor use 

 

The power for the E-941DA series

 

is to be provided by a Listed (UL294 or UL603) Class 2 power supply. 

 

The E-941DA series

 

is intended to be used as an access control system accessory, which is installed in 

accordance with the manufacturer’s installation and operation instructions, ANSI/NFPA 70 and the local 
authority having jurisdiction. 

 

The minimum permissible wire size to be used shall not be less than 22AWG 

 

Summary of Contents for E-941DA-600Q

Page 1: ...le mounting bracket Complete mounting hardware for typical installations L bracket and Z brackets available for easy mounting Detachable faceplate 12 24VDC selectable NOTES UL294 Indoor use The power...

Page 2: ...Current draw 12VDC 500mA 12VDC per door 1A total 24VDC 250mA 24VDC per door 500mA total Bond sensor relay 3A 12VDC Dimensions Magnet 1911 16 x11 16 x15 8 500x26x40 mm 21 x15 8 x25 8 536x42x67 mm Arma...

Page 3: ...ual will make installation much easier 2 The electromagnetic locks are designed for indoor use ONLY 3 The most suitable mounting location for the electromagnetic locks may require the use of additiona...

Page 4: ...ate side of the doors for the armature screws Then drill two 5 8 16mm dia holes for sexnut screws on the opposite side of the doors 5 8 16mm 5 16 8mm Hollow Metal Door Reinforced Door 1 4 6 8mm for M8...

Page 5: ...Put a rubber washer between the two metal washers and place them over the armature screw between the armature plates and the doors This allows the plates to pivot around the screw to compensate for d...

Page 6: ...4VDC Minimum Wire Gauge Wire Length 25ft 50ft 75ft 100ft 150ft 200ft 250ft 300ft 400ft 500ft 1000ft Wire Gauge 500mA 20 18 18 18 16 14 14 12 10 Wire Length 25ft 50ft 75ft 100ft 150ft 200ft 250ft 300ft...

Page 7: ...unlocking Wiring Diagram A fail safe lock unlocks when power is lost so that in case of an emergency such as a fire in the building the fail safe lock will automatically unlock allowing personnel to...

Page 8: ...ipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to replacem...