ELECTROMAGNETIC LOCK Installation Manual

 

 

 

 

 

., 

O A

 U

  c

SECO-LARM U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA  92606

Tel: 800-662-0800 / 949-261-2999   Fax: 949-261-7326

Page 1

Website: www.seco-larm.com

E-mail: sales@seco-larm.com

P TGW1

E-941SA-1K2PDc.pmd

Also available:

HOW IT WORKS

When power is applied to the magnetic lock, it turns on the unit's powerful built-in electromagnet.  This electromagnet is

attracted to the steel armature plate which is mounted on a door, holding the door fast against unauthorized entry.  When
power to the magnetic lock is turned off, the electromagnet releases the armature plate, allowing the door to open.  In

addition, the E-941SA-1K2PD has built-in LEDs to show electromagnet status, plus a status sensor to monitor whether the
door is securely closed, and a built-in adjustable-delay locking timer.

Installation Manual

E-941SA-1K2PD

1200 Pound Holding Force Electromagnetic

Lock with status sensor, LED status display

and adjustable time delay.

SPECIFICATIONS

Power
Magnet Size
Armature Size
Holding Force
Status Sensor
Status LED (2-Color)
Timer Delay
Current Drain
Voltage Tolerance
Housing
Temperature
Weight

E-941SA-1K2PD

12/24 VDC
10½ x 1

5

/

8

 x 2

5

/

8

 in. (268 x 42 x 67 mm)

7

1

/

4

 x 

5

/

8

 x 2

3

/

8

 in. (185 x 16 x 61 mm)

1200-lb (545kg)
Relay, 3A @ 12VDC
Locked - Green, Unlocked - Red
1~78 seconds
500mA @ 12VDC, 250mA @ 24VDC
± 10%
Aluminum
14° ~ 131°F (-10° ~ 55°C)
11-lb (5.0 kg)

E-941DA-1K2P

 -

Double-door 1200 lb. maglock with status
sensor and LED

E-941SA-1200

 - 

1200 lb. maglock without status sensor

E-941SA-600

 - 

600 lb. maglock without status sensor

E-941SA-300

 - 

300 lb. maglock without status sensor

NOTICE:

  

The information and specifications printed in this manual are current at the time of publication.  However,

the SECO-LARM policy is one of continual development and improvement.  For this reason, SECO-LARM reserves the right to

change specifications without notice.  SECO-LARM is also not responsible for misprints or typographical errors.

Copyright © 2011 SECO-LARM U S A., Inc.  All rights reserved.  This material may not be reproduced or copied, in whole or in
part, without the written permission of SECO-LARM.

REGULAR MAINTENANCE

• Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non-abrasive, non-corrosive cleaner.
• Apply a light coat of a silicon lubricant to prevent rust.  Wipe away the excess.
• Check that the armature plate is securely attached to the door, yet can pivot slightly around the armature screw.
• Check that the electromagnet is securely attached to the door frame.

TROUBLESHOOTING

Problem:

• Door does not lock

• Status LED is not

illuminated

Door locks, but can be
easily forced open

Delay in door
releasing

No relay output

Delay in door relocking

Possible cause:

No power

Poor contact between
electromagnet and armature

plate

Incorrect voltage setting

• A secondary diode was

installed across the

electromagnet

• No power

• Misalignment

• Check timer

Solutions:

• Check to make sure the wires are securely tightened to the

terminal block.

• Check that the power supply is connected and operating.

• Make sure the lock switch is wired correctly.
• Make sure the electromagnet and armature plate are

properly aligned.

• Make sure the contact surfaces of the electromagnet and

armature plate are clean and free from rust.

• Check the power leads with a meter, and make sure 12VDC

or 24VDC is present.

• The electromagnet is fitted with a metal oxide varistor to

prevent interference, so do not install a secondary diode.

• Check that the power is connected and operating.

• Make sure the lock is aligned properly.

• Make sure the NO/NC/COM are wired properly.

• Make sure timer is adjusted to desired delay time.

SECO-LARM U.S.A., Inc.

Page 4

SECO

SECO

EC

S

O

SECO----L R

LAR

L R

LARM

M

M

M

LIFETIME LIMITED WARRANTY:

 

 

This SECO-LARM product is warranted against defects in

material and workmanship while used in normal service for the lifetime of the product. SECO-LARM’s obligation is limited to the

repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. Under no

circumstances will SECO-LARM be responsible for any costs or charges for removal, installation, or reinstallation.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair,

or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such

equipment is not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to repair or replacement only, at

SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or

property damages of any kind to the purchaser or anyone else. This lifetime limited warranty is for products sold and installed in

the United States and Canada. For all other countries the warranty is 1 (one) year.

Reviews: