background image

Digital Access Keypad Manual

SECO-LARM U.S.A., Inc.

Digital Access Keypad Manual

12-24V AC/DC universal power

 -- No programming or jumpers needed.

Mantrap

 -- Each keypad can be used as a stand-alone keypad. However, the

mantrap feature uses two keypads to protect an area with two doors by ensuring that
only one door is open at a time. With the mantrap interlock functions, when a user
keys in the code to open one door, a signal is sent to disable the second keypad,
thereby preventing access through the second door until the first door is closed.

Relay output #1 inhibit control

 -- Relay output #1 is typically used for a door strike.

If the keypad is set to the "inhibited" mode, relay output #1 will not operate. This
increases the security of the protected premises during the time it is not expected to
be occupied, such as during evening or weekend hours. An authorized user can
enable or disable the inhibit control by using the code for relay output #2 or output
#3  at any time, depending on how installed.

Door forced open warning

 -- When used with an optional magnetic contact, the

keypad beeps continuously for 1 minute if the door to the protected premises is
forced open without using a valid user code. The warning can be stopped at anytime
by keying in any output #1 user code.

Door propped open warning

 -- When used with an optional magnetic contact, the

keypad beeps continuously if the door is propped open after the allowed open time.
The allowable open time is programmable. The warning stops when the door is re-
closed.

Auto or manual code entry checking:

o Auto code entry checking mode -- When all the user codes have the same number

of digits, the keypad will activate automatically when the code is entered. There is
no need to press the "#" key. This is convenient for the users.

o Manual code entry checking mode -- The user codes can vary in number of digits,

and the user must press the "#" key when finished entering the code. This
increases security.

Keypad active output

 -- This NPN transistor open collector ground (-) output

activates for 10 seconds when any key on the keypad is pressed. This can be used
to trigger a video recorder or turn on a light, or to signal a guard that someone is
entering the protected premises.

Alarm output

 -- When used with an optional magnetic contact, this NPN transistor

open collector ground (-) output can be connected to trigger an optional alarm
control panel if a protected door is forced open or propped open.

Door auto relock

 -- This can be programmed to relock an open door either when the

programmed relock time expires or immediately after the door is closed, depending
on which occurs first. This prevents unwanted "tailgate" entries, which can happen if
an unauthorized person tries to follow an authorized person through the door.

Duress output

 -- This NPN transistor open collector ground (-) output can be used to

trigger a silent alarm if an authorized user is forced under duress to use the keypad.
The duress output is activated by adding 2 to the first digit of any user code for output
#1. In this case, the protected door opens as it would normally, but a signal is quietly
sent to a remote device to call for help without alerting the unauthorized person.

Backlit keypad 

-- The keypad is backlit to increase nighttime visibility.  For convenience,

the lighting intensity will increase for 10 seconds after any key is pressed.

UNIQUE FEATURES

(DEFAULT:              )

#

#

8  4

1

0

Enter Master code

*Key in the Master Code.
Note: For first-time use, Master code is

Confirm

Func ion

Enter into programming mode

Enter Programming Mode

Configure Relay Outputs

Option Output  ime

1 to 999

Confirm

Function

Relay #1, momentary mode, from 1 to 999 seconds
Relay #1, shunt mode (ON/OFF)

X  X   X   X

*

0  0  0  0

#

#

4  0

*

INSTALLER PROGRAMMING

These functions should only be used by professional installers, as incorrect entries can disable the entire keypad function.

0  0  0  0

4  1

Relay #2, momentary mode, from 1 to 999 seconds
Relay #2, shunt mode (ON/OFF)

#

#

5  0

5  1

1 to 999

Output #3, momentary mode, from 1 to 999 seconds
Output #3, shunt mode (ON/OFF)

#

#

6  0

6  1

1 to 999

Wrong Code Lockout

Option # of tries

5 to 10

Confirm

Function
After 10 successive wrong codes, 30-second lockout
After 10 successive wrong codes, Duress activated
After 5 to 10 wrong codes, 15-min. lockout - Can reset wi h Master Code
None of the above

#

#

7  0

7  1

7  2

7  6  0  0

Door Forced-Open Alarm

Op ion Code entry

Confirm

Function

Door forced-open alarm is enabled
Door forced-open alarm is disabled

#

#

8  0

1

0

Output Activation Announcer

Option Code entry

Confirm

Function

1-sec. beep notifies the user to open the door when the output relay is ac ivated.

The beep is disabled, replaced by 2 short beeps for valid user codes.

8  1

User Code Entry Mode

Op ion Code entry

Confirm

Function

Auto Entry Mode

 is selected. The     key that follows  he user code is NOT required in

code entry.  The User Codes MUST be set to  he same digit length as  he Master Code.

Manual Entry Mode

 is selected. The     key that follows the user code is required in

code entry. The User Codes can be 4-8 digits, but not necessarily all of the same length.

#

#

8  2

1

0

#

#

Keypress Beeps

Op ion Code entry

Confirm

Function

Keypad beeps when a key is pressed.

Silent operation -- keypad does not beep when a key is pressed.

#

#

8  3

1

0

Door Propped Open Alarm Timer

Op ion Code entry

Confirm

Function

No door propped open alarm
Allowable time from 1 to 999 seconds that the door can be left open before the alarm starts.

#

#

9

0

1 to 999

Exit Programming Mode

Confirm

Function

Exits programming mode, returns keypad to normal operations

*

(DEFAULT: Momentary, 1-sec. output for all three outputs)

(DEFAULT: 10 tries / 30 seconds)

(DEFAULT: Disabled)

(DEFAULT: On)

{

{

{

{

(DEFAULT: Manual)

(DEFAULT: On)

(DEFAULT: Off)

Data Refresh

Op ion

Confirm

Function

Clears all previously stored data.

#

8  9   0  1

#

#

1

0

{

LED Flashes in Standby Mode

Code entry

Confirm

Function

Amber LED ON during standby mode.
Amber LED OFF during standby mode.

{

(DEFAULT: On)

Page 14

Page 3

Summary of Contents for Enforce SK-1131-SQ

Page 1: ...specifications printed in this manual are current at the time of publication However the SECO LARM policy is one of continual development and improvement For this reason SECO LARM reserves the right t...

Page 2: ...nd 14 to make any changes to the keypad s data 3 Exit the programming mode by pressing the key 1 Disconnect the power supply 2 Move the DAP jumper from OFF to ON 3 Reconnect the power supply The keypa...

Page 3: ...silent alarm if an authorized user is forced under duress to use the keypad The duress output is activated by adding 2 to the first digit of any user code for output 1 In this case the protected door...

Page 4: ...2 3 USER PROGRAMMING ADDING OR CHANGING MASTER AND USER CODES Note No user code may be the same as the master code Note For User ID key in he number of the user For Access Code type in the code for th...

Page 5: ...lts PROGRAMMING NOTES STATUS 1 In programming mode 2 Successful key entry 3 Successful code entry 4 Unsuccessful code entry 5 DAP jumper not replaced 6 In standby mode 7 Output relay activated BUZZER...

Page 6: ...trol is used all personnel must exit the protected premises before output 3 is activated Otherwise personnel in the protected premises will not be able to exit until output 3 is turned OFF The user co...

Page 7: ...ature is for a protected area with two doors to ensure only one door is open at a time With the mantrap feature when a user keys in the code to open one door a signal is sent to the second keypad to d...

Page 8: ...37 38 39 40 41 42 43 44 45 46 47 48 49 USER ID User Name Access Code 00 SAMPLE John Doe 54321 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 8...

Reviews: