background image

 Outdoor Wave-to-Open Sensors 

SECO-LARM U.S.A., Inc. 

Parts List 

1x 

Wave-to-Open Sensor 

2x 

Faceplate screws 

1x 

Wiring harness 

1x 

Manual 

Specifications 

Model 

Slimline 

Single-gang 

European plate 

Double-gang 

Operating voltage 

12~24 VDC 

Current 
draw 
(max.  
±10%) 

Standby red (12/24 VDC) 

13mA / 15mA 

18mA / 23mA 

Triggered green (12/24 VDC) 

21mA / 25mA 

23mA / 29mA 

Standby green (12/24 VDC) 

12mA / 14mA 

14mA / 18mA 

Triggered red (12/24 VDC) 

23mA / 28mA 

28mA / 35mA 

Relay type 

SPDT dry contact, 1.2A@24VDC 

Response time 

10ms 

LEDs 

Standby 

Red* 

Triggered 

Green* 

Output duration 

0.5~30 s, toggle 

Range  

2"~7" (5~18 cm) 

Destructive attack level 

Level I 

Line security  

Level I 

Endurance level 

Level IV 

Standby power 

Level I 

IP Rating 

Weatherproof, IP65

 

Operating temperature 

-4°~131° F (-20°~55° C) 

Weight 

Without override button 

2.2-oz (61g) 

3.8-oz (108g) 

2.7-oz (77g) 

N/A 

With override button  

2.7-oz (77g) 

4.4-oz (125g) 

N/A 

5.6-oz (160g) 

*

Color function reversible 

When properly installed 

Overview 

 

INSTALLATION NOTES: 

 

This product must be electrically wired and grounded in accordance with local codes or, in the absence of local 
codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electrical Code CSA C22.1. 

 

Due to the nature of IR technology, an IR sensor can be triggered by a direct light source such as sunlight, 
reflected light from a shiny object, or other direct light. Therefore, in some locations it may be necessary to install 
a hood or other barrier to shield the sensor from direct light sources.

 

 

SPDT Mechanical Override* 

Sensor layout (except slimline, single-gang shown) 

Slimline sensor layout 

Side 

4

1

/

2

(115mm) 

1

1

/

2

(39mm) 

2

3

/

4

(70mm) 

2

3

/

4

(70mm) 

5-Pin connector 

LED Control jumper 

Trigger duration adjustment 

Sensor range adjustment 

SD-9263-KSVQ 

shown  

(not to scale) 

Other Faceplate 

Dimensions: 

European Plate 

3

3

/

8

"x3

3

/

8

" (86x86 mm) 

Double-Gang 

4

1

/

2

"x4

9

/

16

" (116x115 mm) 

*Models with the manual 

override button only 

Summary of Contents for SD-9163-KSQ

Page 1: ... Wave to Open Sensor is a full featured exit plate using IR technology to allow egress from a protected area or activate a device with the simple wave of a hand Since no touch is required this sensor is suitable for use in hospitals clinics labs cleanrooms to reduce the risk of contamination schools factories or offices Adjustable sensor range up to 7 18cm 1 2A relay adjustable trigger duration 0 ...

Page 2: ... 7 oz 77g 4 4 oz 125g N A 5 6 oz 160g Color function reversible When properly installed Overview INSTALLATION NOTES This product must be electrically wired and grounded in accordance with local codes or in the absence of local codes with National Electric Code ANSI NFPA 70 latest edition or the Canadian Electrical Code CSA C22 1 Due to the nature of IR technology an IR sensor can be triggered by a...

Page 3: ...nging the LED Color Slimline Models Other Models Adjusting the Sensor Range and Output Duration 1 The sensor range can be adjusted from 2 7 5 18 cm 2 Output duration can be adjusted from 0 5 30 seconds or toggle NOTE Do not force the adjustment trimpots to turn Only minimal force is needed Red Wire 12 24 VDC Brown Wire Ground Blue Wire COM Purple Wire N O Green Wire N C Red Wire 12 24 VDC Brown Wi...

Page 4: ...ion prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation ...

Reviews: