Outdoor Wave-to-Open Sensors
2
SECO-LARM U.S.A., Inc.
Parts List
1x
Wave-to-Open Sensor
2x
Faceplate screws
1x
Wiring harness
1x
Manual
Specifications
Model
Slimline
Single-gang
European plate
Double-gang
Operating voltage
12~24 VDC
Current
draw
(max.
±10%)
Standby red (12/24 VDC)
13mA / 15mA
18mA / 23mA
Triggered green (12/24 VDC)
21mA / 25mA
23mA / 29mA
Standby green (12/24 VDC)
12mA / 14mA
14mA / 18mA
Triggered red (12/24 VDC)
23mA / 28mA
28mA / 35mA
Relay type
SPDT dry contact, 1.2A@24VDC
Response time
10ms
LEDs
Standby
Red*
Triggered
Green*
Output duration
0.5~30 s, toggle
Range
2"~7" (5~18 cm)
Destructive attack level
Level I
Line security
Level I
Endurance level
Level IV
Standby power
Level I
IP Rating
Weatherproof, IP65
†
Operating temperature
-4°~131° F (-20°~55° C)
Weight
Without override button
2.2-oz (61g)
3.8-oz (108g)
2.7-oz (77g)
N/A
With override button
2.7-oz (77g)
4.4-oz (125g)
N/A
5.6-oz (160g)
*
Color function reversible
†
When properly installed
Overview
INSTALLATION NOTES:
This product must be electrically wired and grounded in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electrical Code CSA C22.1.
Due to the nature of IR technology, an IR sensor can be triggered by a direct light source such as sunlight,
reflected light from a shiny object, or other direct light. Therefore, in some locations it may be necessary to install
a hood or other barrier to shield the sensor from direct light sources.
SPDT Mechanical Override*
Sensor layout (except slimline, single-gang shown)
Slimline sensor layout
Side
4
1
/
2
"
(115mm)
1
1
/
2
"
(39mm)
2
3
/
4
"
(70mm)
2
3
/
4
"
(70mm)
5-Pin connector
LED Control jumper
Trigger duration adjustment
Sensor range adjustment
SD-9263-KSVQ
shown
(not to scale)
Other Faceplate
Dimensions:
European Plate
3
3
/
8
"x3
3
/
8
" (86x86 mm)
Double-Gang
4
1
/
2
"x4
9
/
16
" (116x115 mm)
*Models with the manual