background image

SECO-LARM Electric Shear Lock 

4

 

SECO-LARM U.S.A., Inc. 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Po

w

er

 In

pu

Fig. 2 -Preparing the 
Mounting Positions 

Width of door 

Outside of door 

when closed 

Door  

Center 

Wiring Diagram: 

1.

 

Set for power supply type (12VDC or 
24VDC) – Use the jumpers to set voltage 
setting (see Fig. 3). 

2.

 

Connect to power 

3.

 

One terminal positive, one to negative 
(non-polarized) 

NOTE:

 When mounting vertically near the center of the door, disassemble the armature 

assembly and add the two included springs. This improves the unit’s push-off. (See 
Fig. 4, pg. 5). 

1.

 

Determine where to mount the armature assembly in the door. It should line up with the 
magnet assembly. (See Fig. 4). 

2.

 

Draw a line between the front and back door faces. This is the door center line (see Fig. 2). 

3.

 

Tape the door template to the door, lining the door template’s door center line with the door 
center line you just drew. 

For Hollow Metal Doors: 

1.

 

Cut out the rectangular piece of metal as shown on the door template. 

2.

 

Drill the four holes (two on each end) as shown on the door template. 

3.

 

Using the included metal screws, mount the mounting tabs. 

For Wood Doors: 

1.

 

Rout or cut a 1

5

/

8

"(42mm) deep, 5

13

/

16

" x 1

3

/

16

" (147x30mm) hole for the cavity of the 

armature assembly as shown in the door template. 

2.

 

Rout a 

3

/

16

" (5mm) deep, 

5

/

8

" x 1

3

/

16

" (17x30mm) hole at each end of the cavity. 

Power  
Supply 

12VDC 

24VDC 

Voltage setting jumpers – Must be set 
properly before connecting power. 
Incorrect settings can damage the 
 SD-993B-SS. 

 

Fig. 3 - Power Supply Settings and Connections 

For Wood Door Frames: 

1.

 

Rout or cut a 1

1

/

16

" (27mm) deep, 

5

13

/

16

"x1

3

/

16

" (147x30 mm) hole for 

the cavity of the magnet assembly 
as shown in the door frame 
template. 

2.

 

Rout or cut a 

3

/

16

" (5mm) deep, 

5

/

8

"x1

3

/

16

" (17x30 mm) hole at each 

end of the cavity. 

3.

 

Run the wires. 

Installation – Cut the Door Frame (Continued):

 

Installation – Cut the Door: 

Control Device 

N.C. contact or relay or keypad 

 

Line 

Summary of Contents for SD-993B-SS

Page 1: ...ssory which are installed in accordance with the manufacturer s installation and operation instructions ANSI NFPA 70 and the local authority having jurisdiction Holding Force has not been verified by...

Page 2: ...Destructive attack Level I Line security Level I Standby power Level I Endurance Level IV Static force 1 500 lb 680kg Dynamic force 70 ft lb Endurance 250 000 cycles Operating temperature 32 120 F 0 4...

Page 3: ...ill show where the door rests relative to the door frame when it is closed d Measure and trace a line between these two lines This is the door frame center line IMPORTANT Make sure the place you choos...

Page 4: ...r line you just drew For Hollow Metal Doors 1 Cut out the rectangular piece of metal as shown on the door template 2 Drill the four holes two on each end as shown on the door template 3 Using the incl...

Page 5: ...me and the armature assembly onto the door 3 Use washers or flat pieces of metal to act as shims as necessary to mount the magnet assembly and armature assembly flush with surface 4 Close the door and...

Page 6: ...or Use 1 x surface mount bracket The magnet assembly is in the bracket above the door and the armature assembly is in the bracket on the door The magnet assembly is flush to the door frame or header a...

Page 7: ...ing SD 993S UB May require 1 or more SD 993S SB and SD 993S UB bracket kits depending on the glass door configuration NOTES One glass door with a glass frame illustrated above Glass Frame 2x Surface m...

Page 8: ...e limited to the replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for any special collateral incidental or consequential personal or property damage of any kind t...

Reviews: