background image

SECO-LARM Electric Shear Lock 

SECO-LARM U.S.A., Inc. 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation – Cut the Door (Continued): 

Adjust armature screws to compensate for the gap between door and frame. (see Fig. 4) 

Fig. 4 Lining up Magnet Assembly and Armature Assembly 

Magnet Assembly 

Locking Bolts 

Push-off 

Button 

Armature 

Assembly 

Armature 

Adjustments 

Screw 

Max. 
2mm Gap 

Armature 

Adjustment 

Screw 

1

1

/

16

 

(2

7m

m

1

1

/

16

 

(2

7m

m

1

5

/

8

 

(4

2m

m

 

1.

 

Double-check your work – Make sure the 
magnet assembly and armature assembly 
line up properly. Make any adjustments. 
(see Fig. 5) 

2.

 

Using the screws provided, mount the 
magnet assembly onto the door frame, and 
the armature assembly onto the door. 

3.

 

Use washers or flat pieces of metal to act 
as shims as necessary to mount the 
magnet assembly and armature assembly 
flush with surface. 

4.

 

Close the door and note the gap between 
the armature assembly and the magnet 
assembly. Using the included hex wrench, 
adjust the nickel-plated portion of the 
armature assembly to make the gap as 
small as possible without interfering with the 
opening and closing of the door. 

5.

 

Apply power and test the operation. 

Installation – Mount the Magnet Assembly and Armature Assembly: 
 

7

1

/

8

" (180mm) 

Use tapping screws 

for wood doors (not 

included). 

Leading edge 

of door. 

NOTE: 

When mounting vertically, disassemble the armature assembly and add extra springs for better push-off. 

5

13

/

16

" (147mm) 

Fig. 5 Mounting the Magnet Assembly 

Summary of Contents for SD-993B-SS

Page 1: ...ssory which are installed in accordance with the manufacturer s installation and operation instructions ANSI NFPA 70 and the local authority having jurisdiction Holding Force has not been verified by...

Page 2: ...Destructive attack Level I Line security Level I Standby power Level I Endurance Level IV Static force 1 500 lb 680kg Dynamic force 70 ft lb Endurance 250 000 cycles Operating temperature 32 120 F 0 4...

Page 3: ...ill show where the door rests relative to the door frame when it is closed d Measure and trace a line between these two lines This is the door frame center line IMPORTANT Make sure the place you choos...

Page 4: ...r line you just drew For Hollow Metal Doors 1 Cut out the rectangular piece of metal as shown on the door template 2 Drill the four holes two on each end as shown on the door template 3 Using the incl...

Page 5: ...me and the armature assembly onto the door 3 Use washers or flat pieces of metal to act as shims as necessary to mount the magnet assembly and armature assembly flush with surface 4 Close the door and...

Page 6: ...or Use 1 x surface mount bracket The magnet assembly is in the bracket above the door and the armature assembly is in the bracket on the door The magnet assembly is flush to the door frame or header a...

Page 7: ...ing SD 993S UB May require 1 or more SD 993S SB and SD 993S UB bracket kits depending on the glass door configuration NOTES One glass door with a glass frame illustrated above Glass Frame 2x Surface m...

Page 8: ...e limited to the replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for any special collateral incidental or consequential personal or property damage of any kind t...