Troubleshooting: 

Problem 

Possible cause 

Solutions 

Door does not 
lock 

No power 

 

Check to make sure the wires are securely 
tightened to the terminal block. 

 

Check that the power supply is connected and 
operating. 

 

Make sure the lock switch is wired correctly. 

Status LED is 
not illuminated 

No power 

Door locks, but 
can be easily 
forced open 

Poor contact 
between 
electromagnet and 
armature plate 

 

Make sure the electromagnet and armature 
plate are properly aligned. 

 

Make sure the contact surfaces of the 
electromagnet and armature plate are clean 
and free from rust. 

Incorrect voltage 
setting 

 

Check the power leads with a meter, and make 
sure 12VDC or 24VDC is present. 

Delay in door 
releasing 

A secondary diode 
was installed across 
the electromagnet 

 

The electromagnet is fitted with a metal oxide 
varistor to prevent interference, so do not install 
a secondary diode. 

No relay output 

No power 

 

Check that the power is connected and 
operating. 

 

Make sure the lock is aligned properly. 

 

Make sure the NO/NC/COM are wired properly. 

Misalignment 

Delay in door 
relocking 

Check timer 

 

Make sure timer is adjusted to desired delay 
time. 

 

Maintenance: 

 

Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non-
abrasive, non-corrosive cleaner. 

 

Apply a light coat of a silicon lubricant to prevent rust. Wipe away the excess. 

 

Check that the armature plate is securely attached to the door, yet can pivot slightly around the 
armature screw. 

 

Check that the electromagnet is securely attached to the door frame. 

 

WARRANTY

  ENFORCER  Electromagnetic  Locks  are  warranted  against  defects  in  material  and 

workmanship  while  used  in  normal  service  for  a  period  of  one  (1)  year  from  the  date  of  sale  to  the 
original customer. Our obligation is limited to the repair or replacement of any defective part if the unit 
is returned, transportation pre-paid, to SECO-LARM. 

 

NOTICE 

The information and specifications printed in this manual are current at the time of publication. 

However, the SECO-LARM policy is one of continual development and improvement. For this reason, 
SECO-LARM  reserves  the  right  to  change  specifications  without  notice.  SECO-LARM  is  also  not 
responsible for misprints or typographical errors. 

Copyright © 2010 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced 
or copied, in whole or in part, without the written permission of SECO-LARM. 

 

SECO-LARM

®

 U.S.A., Inc. 

16842 Millikan Avenue, Irvine, CA 92606 

Website: www.seco-larm.com  

Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326 

E-mail: sales@seco-larm.com 

MiE-941SA-1K2PQ_1012 .docx 

 

 

PITSW2 

 

 

 

1200-lb Electromagnetic Lock Series

 

Manual 

 

 

 

 

How it works 

When power is applied to the magnetic lock, it turns on the unit's powerful built-in 
electromagnet. This electromagnet is attracted to the steel armature plate which is mounted on 
a door, holding the door fast against unauthorized entry. When power to the magnetic lock is 
turned off, the electromagnet releases the armature plate, allowing the door to open. In 
addition, the E-941SA-1K2PQ & E-941DA-1K2PQ have built-in LEDs to show electromagnet 
status, plus a status sensor to monitor whether the door is securely closed. 
 

 

E-941SA-1K2PQ 

Single Door 

w/ Status Sensor 

E-941SA-1K2PDQ 

Single Door 

w/ Status Sensor 

and Timer 

E-941DA-1K2PQ 

Double Door 

w/ Status Sensor 

 

Note: Products with model numbers that end with “Q” or that have a round green “Q” sticker are RoHS compliant. 