36
Start the heating cycle by pressing key on the sliding support.
Display is flashing during the heating cycle.
Heating stops after presetted time or by pressing key .
On completion of the heating cycle, module stays in standby mode avoiding any handling
during 30 seconds. Display will scroll until end of the standby time.
Note : standby mode can not be interrupted. The driving of the X1 outlet is independant.
Fit manually the tool in the bore. The tool will be shrink-grip within 3 to 5 seconds.
Note : on completion of the heating cycle, it is imperative to
immediately remove the inductor housing from the tool in order
to avoid heat spreading into the inductor housing (risk of
deterioration).
Always wear protective gloves while handling Shrinkfit holders, tools,
accessories and spare parts.
6.3
Shrink-release
Preparation for shrink-release is the same as for shrink-grip. Introduction of the tool is
replaced by its ejection.
Always wear protective gloves while handling Shrinkfit holders, tools,
accessories and spare parts.