- This shrinking device is only intended for professional use.
-Take care to use the correct power supply : only the heating module must be connected on AC 3x400V (+/-10%)
+ PE/ 16A/ 50-60 Hz. Power supply for the support modules is : PE/16A/50-60Hz. Use optional transformers
to accommodate shop electric service from 190 to 510V 3X in USA or CSA for Canadian voltage. Both transformers
output PE/16A/50-60Hz for support modules.
- By nature on, the Shrinkfit holder becomes very hot. Touching this spot may cause serious burns. Always wear
gloves when handling Shrinkfit holders.
- Individuals who carry medical implants are banned from using or working with this device. The carriers of a
pacemaker must refer to the specific note of the pacemaker established on the basis of : NF EN 60601-1-2 (september
2007),
- Repairs on the shrinking devices should only be made by skilled operators. Please contact Seco-EPB.
- Only trained and authorized persons are allowed to work on the shrinking devices.
- The support modules are not switched off by main interruptor (red power switch) of the heating module. Before any
handling it’s necessary to switch off the power supply by each module’s interruptor.
10. SAFETY PRECAUTIONS
11. RECOMMENDATIONS FOR USE AND MAINTENANCE
12. SAFETY FUNCTIONS OF HEATING MODULE
-Technical features,
- Compliance declaration for heating modules, support and cooling boxes (to fill in)
- Certificate.
13. ANNEXES
- Always make sure the holder is cooled down before shrink grip, or shrink release.
- The holder and the tool must be clean, free from grease and dry before being fitted into the device.
- Before starting the shrinking process, please always check if :
- the power supply is sufficient
- the length has been correctly setted, with the correct stop rod
- the correct diameter is selected (mode PRG 1 or PRG 2)
- the correct heat focusing stopper has been setted
- recommended cylindrical tool shank tolerance is h5 or h6 (maximum h5 for Ø 3 to 5 mm,
maximum h6 for Ø 6 to 32 mm).
- the tool shank is not damaged
- Keep the device and its environment clean, to insure a long service life.
- The device can only be used for the purposes defined in this operating book. Seco-EPB cannot be held as
responsible for casualties caused for any other use.
- Maintenance is limited on a regular cleaning of the device and accessories with adapted products.
- The inductor is equipped with a probe to avoid overheating of the holders.
- To increase service life of the holders, the electronic of the device has been programmed to allow only one main
heating process, afterwards it automatically cuts off.