3.3.5
eDP Connector
SBC-C31 offers, a dedicated embedded Display Port interface.
For the connection of this kind of displays, on-board
there is a VESA
®
certified connectors for embedded
Display Port interface, type STARCONN p/n 300E40-
0110RA-G3 or equivalent (microcoaxial cable
connector, 0.5mm pitch, 40 positions).
eDP_LCD_PWR can be factory regulated to be connected to +5V_ALW or +3.3V_ALW, while
eDP_BKLT_PWR can be factory regulated to be connected to +5V_ALW or +12V_ALW.
These are factory configurations, please take care of specifying which is the configuration
needed for eDP_LCD_PWR and eDP_BKLT_PWR voltage rail.
Here following the signals involved in eDP management:
eDP_ML0P/eDP_ML0N: embedded DP differential data pair #0.
eDP_ML3P/eDP_ML1N: embedded DP differential data pair #1.
eDP_ML3P/eDP_ML2N: embedded DP differential data pair #2.
eDP_ML3P/eDP_ML3N: embedded DP differential data pair #3.
eDP_AUX_P/eDP_AUX_N: embedded DP auxiliary channel differential data pair.
eDP_BKLT_EN: eDP_LCD_PWR electrical level Output with a 1k
Ω
pull-up resistor, Backlight
Enable signal. It can be used to turn On/Off the backlight
’
s lamps of connected displays.
eDP_BKLT_PWM: this signal can be used to adjust the backlight brightness in displays
supporting Pulse Width Modulated (PWM) regulations (eDP_LCD_PWR electrical level).
eDP connector - CN33
Pin Signal
Pin Signal
1
---
21
eDP_LCD_PWR
2
eDP_BKLT_PWR
22
eDP_LCD_PWR
3
eDP_BKLT_PWR
23
eDP_LCD_PWR
4
eDP_BKLT_PWR
24
GND
5
eDP_BKLT_PWR
25
eDP_AUX_N
6
---
26
eDP_AUX_P
7
---
27
GND
8
eDP_BKLT_PWM
28
eDP_ML0P
9
eDP_BKLT_EN
29
eDP_ML0N
10
GND
30
GND
11
GND
31
eDP_ML1P
12
GND
32
eDP_ML1N
13
GND
33
GND
14
---
34
eDP_ML2P
15
GND
35
eDP_ML2N
16
GND
36
GND
17
GND
37
eDP_ML3P
18
GND
38
eDP_ML3N
19
---
39
GND
20
eDP_LCD_PWR
40
---