/ LVDS_B3-: LVDS Channel #1 differential data pair #3.
LVD / LVDS_B_CLK-: LVDS Channel #1 differential Clock.
BLT_EN: VCC_LCD electrical level Output with a 10k
Ω
pull-up resistor, Backlight Enable signal. It can be used to turn On/Off the backlight
’
s lamps of connected
displays.
LVDS_PPEN: VCC_LCD electrical level Output with a 10k
Ω
pull-up resistor, Panel Power Enable signal. It can be used to turn On/Off the connected display.
BLT_CTRL: this signal can be used to adjust the backlight brightness in displays supporting Pulse Width Modulated (PWM) regulations (VCC_LCD electrical level).
LVDS_BLT_ANA: Analog dimming for LVDS panel backlight, electrical level ranging from 0V up to VCC_LCD
TOUCH_SCL: I2C Bus clock line on pin 45 and 50. Bidirectional signal, electrical level VDD_3V3 with a 2K2
Ω
pull-up resistor. It is managed by the processor
’
s
LVDS0_I2C1_SCL.
TOUCH_SDA: I2C Bus data line on pin 47 and 49. Bidirectional signal, electrical level VDD_3V3 with a 2K2
Ω
pull-up resistor. It is managed by the processor
’
s
LVDS0_I2C1_SDA.
TOUCH_RST: VDD_3V3 electrical level output, active high signal with a 100k
Ω
pull-down resistor. This signal can be used to drive a reset of an eventual external
Touch Screen connected to the dedicated I2C interface.
TOUCH_INT#: VDD_3V3 electrical level input, active low signal with a 100k
Ω
pull-up resistor. This signal can be used to serve the interrupt request of an eventual
external Touch Screen connected to the dedicated I2C interface.