background image

 

Valve box 

Holder cover 

(B)

 

Overall cover 

packing 

Fig 2-C 

Fig 2-D 

Diaphragm holder 

Solenoid 

Magnet 

D

 

(C)

 

 

 

Undo  the  screws  (B)  and  remove  the  holder 
cover. (Ref: Fig 2-C) 

 

 

Undo the screws (C) and replace the valve box 
of both sides. (Ref: Fig 2-C) 

 

 

Undo  the  nuts  (D)  and  remove  diaphragm 
holders and diaphragms from the magnet. (Ref: 
Fig 2-D) 

 

 

Set the new diaphragm holders and diaphragms 
and  fasten  them  with  the  nuts.  (D).  (  Ref:  Fig 
2-D) 

 
Notes: 
Use the new nuts (D) in the repair kit. 
Note the locating notch for reassembly. 
 

 

Assemble 

by 

reversing 

the 

disassembly 

procedure. 

 
Notes: 
Keep the magnet from touching the solenoids. 
 

 

Check airflow and sound level before installation. 

 
 
 
 
 
 
 
 
 
 
 
 
 

 Automatically reset thermal protector 
 

An automatically reset thermal protector installed on the solenoid stops pump 
operation  if  solenoid  temperature  becomes  over  130  ±  5 

.  When  the 

solenoid  temperature  cools  down  to  85  ±  15 

,  the  protector  is  reset 

automatically and pump operation restarts. 

 

 

Do not touch live parts. Touching live parts will result in electric shock. 

 

 

 

If  the  magnet  contacts  the  solenoids  during  operation,  it  will  cause 
damage on parts, abnormal heat, and short circuiting. 

 