background image

 

 Trouble shooting 

Observation 

Possible cause 

Action 

Pump does not   
operate. 

 

Improper  electrical   

        connection 

 

Check  plug  and  outlet
  and  plug  completely. 

Discharge  air   
decreased. 
 
Pump  surface   
is  abnormally   
hot. 
 
Pump  operates   
intermittently 
 

 

Pipe  or  diffuser  clogged   

 

Valve  in  plumbing  shut 

 

Filter  element  clogged 

 

 

Clean  pipe  or  diffuser. 

 

Open  the  valve 

 

Clean  filter  element. 

 

Pump  operates   
but  with   
abnormal  noise. 

Faulty  valve  or  diaphragm 

 

Replace  valve  and   

        diaphragm. 

 

 Replacement parts 

Kit name 

Contained parts 

Quantity (pcs) 

Diaphragm repair kit for JDK 

Diaphragm 

Diaphragm holder 

Nut 

Valve box   

Filter element 

Overall cover packing 

Reviews: