M00   Control  Panel

 No  entry  delay

No

Short  programming manual - basic information 

Intruder alarm system

System with  

KM24, KM24A

, KM24G keypads

PARTITIONS

MODULES

Partitions allow you to break up a large area into smaller sections. This feature is useful to disarm certain areas while leaving other areas 
armed, or to limit access of certain areas to other users.

Control panel 

PAS808M

 support

s

 up to 7 modules

 and

 control panels 

PAS8

16, PAS832, P16, P32, P64

 supports up to 15 modules.

P01   Apartment

1

 

 Name

Apartment

Service Mode 

}

System Setup 

}

Modules 

}

 Module settings

It is recommended to give an appropriate name to a partition. The system will use it 

when sending

 SMS or 

when 

show

ing

 status of the partition on keypad's LCD. 

For next character possition press [



]

 

or [

] key. 

Move the 

cursor on the wrong character to delete it and press [0].

2

 

P01   Apartment

 In Use

 Yes

The alarm system can be divided into 4 partitions for operating flexibility.

 

Confirm the activation of 

new 

partition by selecting 

Yes

. Press 

[

Ü

]

 or [7] for the next partition.

Exit Delay

 time can be different for each partition in control panels PAS816v3, PAS832v3, P16, P32, 

and 

P64.

3

 

P01   Apartment

 Exit Delay

 30 sec

4

P01   Apartment

 No  entry  delay

 No

This setting changes entry delay time in partition to 0 seconds (excluding PAS808M). User should remotely 
disarm the system before entering partition.

3

 

P01   Apartment

 Arming  timer

[ENT]

3

 

P01   Apartment

 Pre-Alarm timer

[ENT]

In this menu it is possible to assign the timer(s) to partition. Auto-arming starts at a specific time of day and arms 
the partition in 

Stay

 mode. Auto-arming will be aborted if any of the zones in partition will be violated or trouble 

will appear during exit delay. Use

 

the

 

[ENT] key to 

access

 

the 

menu, then press [#] to assign 

timer to

 the

 

partition. Save changes by pressing the [ENT] key. 

Note:

 if you see dashes (---) instead of [ENT], it means that 

no timers are programmed in the system (program system timers in the menu:

 Main menu 

}

 

S

ettings

 

}

Timers

).

In this menu it is possible to assign the timer(s) to partition. Auto-arming starts at a specific time of day and arms 
the partition in 

Pre-Alarm

 mode. Use

 

[ENT] key to 

access

 menu, then press [#] key to assign 

timer to

 the

 

partition. Save changes by pressing the [ENT] key. 

Note: 

if you see dashes (---) instead of [ENT], it means that 

no timers are programmed in the system (program system timers in menu:

 Main menu 

}

 

S

ettings

 

}

Timers

).

M00   Control  Panel

1

 

 Name

Control  Panel

It is recommended to give an appropriate name to the module. The module name  will appear on keypad

’s

 LCD if 

there will be a

ny

  trouble  with the module. 

2

 

M00   Control  Panel

 Address

 00

Registered module address is shown in a second row and on the upper-left corner of LCD (eg. M00 = 00 
address). Please remember the module address and use it to program zones and PGM outputs.

3

 

M00   Control  Panel

 Type

 PAS832

Registered module type is shown on LCD. Available module types: PAS816, PAS832, P16, P32, P64,

 PWR20,

 

KM24, KM24A, KM24G, EXT116S, GSV6U, GSVU, EXM800, PROX8, and LAN800.

4

M00   Control  Panel

 Serial  No.

805308385

Registered module serial number is shown on LCD. If you don't see modules serial number, it means that the 
module is not registered in the system. See page 2 for more information about manual module registration.

5

 

M00   Control  Panel

 Use module tamper

Yes

For additional security it’s recommended to use tamper to protect modules. Tamper can be activated by using:
      Z6 - on control panels;
      Z1 - on EXM800;
     

TMP

  - on 

PWR20

;

      back switch - on keypads.
If 

Use module tamper

 is selected as 

No

, then zones Z6 on control panel and Z1 on EXM800 can be used as 

regular zone terminals.

Basic settings for all modules:

Extended settings for control panel:

Keypad's screen will show PGM trouble when the load on a preprogrammed PGM output will not be detected by 
the control panel. By default PGM load detection is disabled.

7

 

M00   Control  Panel

 PGM  load  detection

No

8

 

9

 

10

 

M00   Control  Panel

 Cut-off  +BELL
 Cut-off  -PGM(1)
 Cut-off  +PGM(2)

Yes

Yes

No

Control panel can be programmed to cut-off the PGM output when it detects battery's voltage is approaching a 
critical level of discharge

The threshold is 11,5V.

This setting changes entry delay time in all partitions to 0 seconds (for PAS808M only). User should remotely 
disarm the system before the entering partition.

12

 

M00   Control  Panel

 Arm  anyway

No

13

 

M00   Control  Panel

 EXT116VM count

4

Usually the system stops counting exit delay if system’s zone is violated during the exit delay. If this setting is set 
to 

Yes, 

then the system will continue counting the exit delay and will sound an alarm if any of the zones will be 

violated during exit delay.

All virtual wireless modules EXT116VM are usually enabled by default. DO NOT FORGET to run an automatic 
module registration if this setting was changed.

Service Mode 

}

System Setup 

}

Partitions

Page 3

Summary of Contents for BK4

Page 1: ... the tab Project data sending receiving 3 Once you customize the predefined template you can use it to program an individual system or thousands of systems 4 DO NOT FORGET to upload the customized template further project back to the keypad use the tab Project data sending receiving Fig 1 USB connection Upon power up of the system the keypad will display a phrase First Start Press ENT It means tha...

Page 2: ... the customized project back to the keypad use the tab Project data sending receiving MANUAL REGISTRATION OF MODULES Control panel PAS808M supports up to 7 modules and control panels PAS816 PAS832 P16 P32 P64 supports up to 15 modules If there are a few modules with incl enabled virtual modules EXT116VM on P series control panels the same default addresses in the system for example several EXM800 ...

Page 3: ...s are programmed in the system program system timers in menu Main menu Settings Timers M00 Control Panel 1 Name Control Panel It is recommended to give an appropriate name to the module The module name will appear on keypad s LCD if there will be any trouble with the module 2 M00 Control Panel Address 00 Registered module address is shown in a second row and on the upper left corner of LCD eg M00 ...

Page 4: ... MC and IR Anti Sabotage Roller Anti Sabotage No 5 6 M06 PROX8 Unknown tag No actio 13 The proximity reader has 3 options on what it must do when the unknown proximity tag is detected No action Indication module starts blinking red and starts emitting an annoying noise Indication and alarm module starts blinking red and starts emitting an annoying noise The alarm siren will be triggered after 3 at...

Page 5: ...e Roller special purpose zone loop type exluding PAS808M Wireless Z01 Door Address 00_1 A 2 Z01 Door Address 00_1 B 2 Page 5 Wireless detectors can be enrolled using serial number in a system with following firmware version or higher control panel P16 P32 P64 v 5 00 wireless zone expansion module EXT116S v 5 000 keypads KM24 KM24Aarba KM24G v 5 000 keypads KM25 v 5 000 software MASCAD v 1 9403 GSM...

Page 6: ...m is armed in Stay mode Entry Exit Forced same as Entry Exit zone but unlike a regular entry exit zone this zone can be violated before the arming Short programming manual basic information Intruder alarm system System with KM24 KM24A KM24G keypads Z01 Door Supervisory window 2h 6 Specifies how often the system checks for supervision signals identifying each of the system s wireless detectors The ...

Page 7: ...tput triggering source otherwise the PGM will not work correctly Not used unused PGM output should be programmed as Not Used FireAlarm output activates if an alarm occurs on the selected zone or module emergency keys Fire Burglary Alarm output activates if fire or burglary alarm occurs on the selected zone or module emergency keys Note output also activates when zone or module tamper conditions ar...

Page 8: ...eporting to CMS or to the user via the PSTN line PSTN Communicator Tel Number 1 8p45345464 2 Program the phone numbers as required Use the key to enter additional symbols p 3 sec pause P 10 sec pause w wait dial tone User must acknowledge the call by pressing the Ü key on the phone otherwise the control panel will call again Program the Account number This account number will be used for all repor...

Page 9: ...twork and another computer network frequently the public Internet A GSM GPRS module making a data connection must be configured with an APN to present to the network provider Contact your provider to verify the correct APN settings 4 GPRS settings Yes Send every 15 sec Periodic test The Periodic test menu enables you to set the time period that the module will automatically send a test report to t...

Page 10: ...in hours Period in hours Report time hh mm Report time hh mm x 1 1 x 01 00 xx 15 1 1 2 2 3 3 The programmed exit delay will be applied for all enabled partitions System Times Exit Delay 30 sec 1 Used for all partitions An audible Auto Arm Delay warning countdown will commence prior the automatic arming User that has right to stop auto arming can enter a valid PIN code at any time during the countd...

Page 11: ...stribution the wireless devices detectors PGM outputs and remote control can be programmed at factory to operate on different frequency Receiver can receive a signal from transmitter when operating frequency matches Wireless Subsystem 4 Attenuation 0 dB Due to the fact that there may be changes in the passive environment after installation it is possible to temporarily for 3dB attenuate the radio ...

Page 12: ... from the user U01 User 01 U01 User 01 Rights Arm Disarm Yes Clear alarm Yes Abort arming Yes All Rights Selected 7 7 All system users have all rights assigned by default However it is possible to change them The user has access to the following Arm Disarm Clear alarm Abort arming Bypass zones Edit settings View Event log Test fire zones Reporting test Run other tests Control PGM outputs Edit syst...

Page 13: ...GISTER KEYPAD KM24G PROGRAMMING WIZARD KM24G Service Mode Unregister Modules Service Mode Unregister keypad Service Mode Programming Wizard Used to unregister system modules The message First Start Press ENT will appear on keypad s LCD screen when this procedure will end Used to unregister the keypad from the system Step by step programming wizzard with explanations and wiring schemes 5 7 6 Servic...

Page 14: ...Use SERIALaccount Account number Protocol Transport Receiver No 2 Use as backup for Rec 1 Address Port Use SERIALaccount Account number Protocol Transport Periodic test Send every Obtain IPautomatic IPaddress Subnet mask Gateway Obtain DNS automatic DNS server 1 DNS server 2 Periodic Test Settings Period in hours Period in days Period time hh mm Name In Use Exit Delay No Entry Delay Arming timer P...

Reviews: