background image

NC t

ype detector

 (BK2, BK3, BK4)

2  

1  

0

input  terminal  1,  2  or  3. 

Z

one 

response

  (speed) 

time  of 

0,4 

sec.

Short  programming manual - basic information 

Intruder alarm system

System with  

KM24, KM24A

, KM24G keypads

Z01   Door

 Address

00_1

2

Zone address is a 3-digit number represented in MA_Z format, where MA specifies a module address in the 
system and 

Z

 specifies a zone terminal in the module board. Example: 

00_1

 - 

where 

00 means the control panel 

and 1 means zone terminal Z1. To program a doubled zone - detectors A and B must be specified. Use keypad 
keys [A] or [B] to specify these detectors in the zone address field (example: 00_1 A, 00_1 B, ...). 

Note:

 use loop types 

NO/DEOL

 or 

NC/DEOL

 for the doubled zones.

For a keypad firmware version to v.5.xxx, wireless zone loop type depends on zone address. For wireless zones 
MA_1 – MA_8 the system will automatically assign 

NO/DEOL

 loop type and for wireless zones MA_9 – MA_16 

the 

Vibration

 loop type. Do not change the loop type of the zone!

For a keypad firmware version v.5.xxx or higher the loop type is 

Wireless 

for all wireless zones MA_1 – MA_16.

Wireless m

odule address

:

   

  EXT116S - 

address

 

06

 (

default

or one that is given during the registration process.

Virtual 

wireless 

module EXT116

VM

 address:

     

P16 - 

address

 

12

;

     

P32 - 

address

 

12

 

and

 

13

;

     

P64 - 

address

 

12

13

14

 and

 

15

.

Z01   Door

 Loop  Type

NC

3

The 

Loop type

 menu enables you to program the connection type used for each of the system’s zones. The 

actual (physical) loop type for each zone must comply with that selected in the 

Loop type

 menu. Available loop 

types:
     

Not used

     

NC - 

uses normally closed contacts and no end of line resistor;

     

NO - 

uses normally open contacts and no end of line resistor;

     

NC/EOL - 

uses normally closed (NC) contacts in a zone terminated by a 1k end of line resistor;

     

NO/EOL - 

uses normally open (NO) contacts in a zone terminated by a 1k end of line resistor;

     

NC/DEOL - 

uses normally closed (NC) contacts in a zone using at least two 1k end of line resistors to 

distinguish between alarms and tamper conditions;
     

NO/DEOL - 

uses normally open (NO) contacts in a zone using at least two 1k end of line resistors to 

distinguish between alarms and tamper conditions;
     

Vibration - 

special purpose zone loop type;

     

Roller - 

special purpose zone loop type

 (exluding PAS808M)

;

 

 

 

Wireless

Z01   Door

 Address

00_1 A

2

Z01   Door

 Address

00_1 B

2

Page 5

Wireless detectors can be enrolled

 using serial number in a system with following firmware version or higher:

 

  control panel P16, P32, P64 – v.5.00;

 

 

  wireless zone expansion module EXT116S – v.5.000;

 

 

  keypads KM24, KM24A arba KM24G – v.5.000;

 

 

  keypads KM25  – v.5.000;

 

 

  software MASCAD – v.1.9403;

 

 

  GSM/GPRS communicator GSVU or GSV6U – v.5.000;

 

 

  LAN communicator LAN800 – v.5.00.

 

Enrolment using serial number is a two step process

:

 

 

 

 

1 step.

 Enter detector serial number. The keypad will identify the detector's type and will show all other 

related settings that are required for enrolment.

 

 

 

 

2 step.

 SERVICE MODE DOES NOT HAVE TO BE ENTERED AT THIS STEP! To complete enrolment, 

the detector must be activated to send a signal to the receiver. It could be done by triggering the detector’s 
loop (zone) OR by pressing the tamper switch. All wireless detector zones that are still not activated, therefore 
not enrolled, are marked with a phrase 

Not activ.

 in menu 

Wireless communication.

Z01   Door

 Model
 Loop (zone)

 Detect tamper
 Battery
Operation code

 Serial No.

4

8388608

BK4

Magnetas

Taip

ER14250

201

5

Z01   Door

 Serial No.

4

N/A

When the detector is successfully enrolled, the mode 

LR

 or 

ES

 will be displayed in the row. Phrase 

No SN

.

 will be 

displayed when wireless zone is enabled, but serial number of the detector is not entered. Phrase 

only LR 

will be 

displayed when the detector supports only the 

LR

 mode (firmware version < 2.000).

   

}

Techn

ical information

 

}

Wireless communication

Wireless communication

Entry doors
Window
Living room
Kitchen

Detector status

1

Not activ.

LR

No SN.

only LR

2

3

4

Z01   Door

 

Operation  code

N/A

4

Wireless detector can also be enrolled using 

Operation code

. Enter wireless detector’s 

peration code

 and 

O

press

 

the [ENT] key. When enrolment has started, immediately press the detector's tamper switch for a short 

period of time (~1 sec).

200

Temperature

(BT1)

201

Magnet

(BK1, BK4)

Water leakage 
detector (BF1)

0

10

181

Motion

(BP2)

180

Temperature

(BP2)

Wireless output BS100. 

the LAST digit of the 

Operation code

 which 

Important

!

 

 

was 

used for enrolling BS100 indicates the wireless PGM output number in the module.

1

02

1

03

1

04

1

05

Input terminal (1, 2, 3). 

2  

1  

1

L

ast digit defines the number of Roller 

pulses

 (1, 2, 3, 4, 5, 7, 9).

D

elete 

single

detector

254

Delete all detectors 

from module

255

Summary of Contents for BK4

Page 1: ... the tab Project data sending receiving 3 Once you customize the predefined template you can use it to program an individual system or thousands of systems 4 DO NOT FORGET to upload the customized template further project back to the keypad use the tab Project data sending receiving Fig 1 USB connection Upon power up of the system the keypad will display a phrase First Start Press ENT It means tha...

Page 2: ... the customized project back to the keypad use the tab Project data sending receiving MANUAL REGISTRATION OF MODULES Control panel PAS808M supports up to 7 modules and control panels PAS816 PAS832 P16 P32 P64 supports up to 15 modules If there are a few modules with incl enabled virtual modules EXT116VM on P series control panels the same default addresses in the system for example several EXM800 ...

Page 3: ...s are programmed in the system program system timers in menu Main menu Settings Timers M00 Control Panel 1 Name Control Panel It is recommended to give an appropriate name to the module The module name will appear on keypad s LCD if there will be any trouble with the module 2 M00 Control Panel Address 00 Registered module address is shown in a second row and on the upper left corner of LCD eg M00 ...

Page 4: ... MC and IR Anti Sabotage Roller Anti Sabotage No 5 6 M06 PROX8 Unknown tag No actio 13 The proximity reader has 3 options on what it must do when the unknown proximity tag is detected No action Indication module starts blinking red and starts emitting an annoying noise Indication and alarm module starts blinking red and starts emitting an annoying noise The alarm siren will be triggered after 3 at...

Page 5: ...e Roller special purpose zone loop type exluding PAS808M Wireless Z01 Door Address 00_1 A 2 Z01 Door Address 00_1 B 2 Page 5 Wireless detectors can be enrolled using serial number in a system with following firmware version or higher control panel P16 P32 P64 v 5 00 wireless zone expansion module EXT116S v 5 000 keypads KM24 KM24Aarba KM24G v 5 000 keypads KM25 v 5 000 software MASCAD v 1 9403 GSM...

Page 6: ...m is armed in Stay mode Entry Exit Forced same as Entry Exit zone but unlike a regular entry exit zone this zone can be violated before the arming Short programming manual basic information Intruder alarm system System with KM24 KM24A KM24G keypads Z01 Door Supervisory window 2h 6 Specifies how often the system checks for supervision signals identifying each of the system s wireless detectors The ...

Page 7: ...tput triggering source otherwise the PGM will not work correctly Not used unused PGM output should be programmed as Not Used FireAlarm output activates if an alarm occurs on the selected zone or module emergency keys Fire Burglary Alarm output activates if fire or burglary alarm occurs on the selected zone or module emergency keys Note output also activates when zone or module tamper conditions ar...

Page 8: ...eporting to CMS or to the user via the PSTN line PSTN Communicator Tel Number 1 8p45345464 2 Program the phone numbers as required Use the key to enter additional symbols p 3 sec pause P 10 sec pause w wait dial tone User must acknowledge the call by pressing the Ü key on the phone otherwise the control panel will call again Program the Account number This account number will be used for all repor...

Page 9: ...twork and another computer network frequently the public Internet A GSM GPRS module making a data connection must be configured with an APN to present to the network provider Contact your provider to verify the correct APN settings 4 GPRS settings Yes Send every 15 sec Periodic test The Periodic test menu enables you to set the time period that the module will automatically send a test report to t...

Page 10: ...in hours Period in hours Report time hh mm Report time hh mm x 1 1 x 01 00 xx 15 1 1 2 2 3 3 The programmed exit delay will be applied for all enabled partitions System Times Exit Delay 30 sec 1 Used for all partitions An audible Auto Arm Delay warning countdown will commence prior the automatic arming User that has right to stop auto arming can enter a valid PIN code at any time during the countd...

Page 11: ...stribution the wireless devices detectors PGM outputs and remote control can be programmed at factory to operate on different frequency Receiver can receive a signal from transmitter when operating frequency matches Wireless Subsystem 4 Attenuation 0 dB Due to the fact that there may be changes in the passive environment after installation it is possible to temporarily for 3dB attenuate the radio ...

Page 12: ... from the user U01 User 01 U01 User 01 Rights Arm Disarm Yes Clear alarm Yes Abort arming Yes All Rights Selected 7 7 All system users have all rights assigned by default However it is possible to change them The user has access to the following Arm Disarm Clear alarm Abort arming Bypass zones Edit settings View Event log Test fire zones Reporting test Run other tests Control PGM outputs Edit syst...

Page 13: ...GISTER KEYPAD KM24G PROGRAMMING WIZARD KM24G Service Mode Unregister Modules Service Mode Unregister keypad Service Mode Programming Wizard Used to unregister system modules The message First Start Press ENT will appear on keypad s LCD screen when this procedure will end Used to unregister the keypad from the system Step by step programming wizzard with explanations and wiring schemes 5 7 6 Servic...

Page 14: ...Use SERIALaccount Account number Protocol Transport Receiver No 2 Use as backup for Rec 1 Address Port Use SERIALaccount Account number Protocol Transport Periodic test Send every Obtain IPautomatic IPaddress Subnet mask Gateway Obtain DNS automatic DNS server 1 DNS server 2 Periodic Test Settings Period in hours Period in days Period time hh mm Name In Use Exit Delay No Entry Delay Arming timer P...

Reviews: