-- page 1 --
E4000R-Generalcode-Betriebsanleitung-Version 5.2.2.1.1-englisch.p65
Subject to technical modifications
Date: 04.01
NUMBER LOCK WITH 111 MILLION GENUINE
SETTING CONFIGURATIONS
Operating Instructions for Electronic Lock
E4000R with Opening Delay and Mastercode,
Version 5.2.2.1.1 (until 03/2001)
All-redundant electronic lock E4000R (approved in VdS class 2) with a mastercode serves as an electronic central locking
station, allowing up to 9 sub-levels (standard numerical codes of 6 to 8 figures) to be selected, modified or canceled from
the main level (the 9-figure mastercode). The E4000R can be programmed from outside to either set the lock for
immediate access after entering the correct numerical code, or for delayed access after a pre-set waiting period.
OPENING THE SAFE OR STRONGROOM
1. Press EIN/ON key.
2. After a short, high-pitched signal tone, either key-in the 9-figure mastercode or one of the the 6- to 8-figure standard
codes (factory setting of only the mastercode: 1 2 3 4 5 6 7 8 9).
3. Press ENTER key - you will hear the short, high-pitched signal tone again. A short, low-pitched signal tone indicates
that you entered the wrong code. If the opening delay is set to 0 (zero) minutes (factory setting), please proceed with
step 6.
4. Wait for the set opening delay to lapse. During the waiting time, the safe cannot be opened. The end of the opening
delay is indicated by short, high-pitched signal tones (lasting 30 seconds).
5. Press ENTER key before the sounding of the signal tones ceases and re-enter the valid numerical code. Complete
by pressing the ENTER key.
6. Open the lock by the lock handle by turning it a half turn. The electronics will switch itself off automatically after
5 seconds.
7. Now open the door by turning the door handle.
SECURING THE SAFE OR STRONGROOM
If it should only be possible to open the safe or strongroom by entering the numerical code, the door and lock handles
have to be turned back in their original position (first lock the door, then the lock).
LOCKING THE SAFE OR STRONGROOM
The safe or strongroom is locked by turning the door handle. It can then be opened without re-entering of the numerical
code.
REMARKS
- After keying-in a wrong number, the number combination can be deleted by pressing the EIN/ON key. After that
the opening procedure can be repeated.
- After keying-in the wrong number combination two times in a row, the electronic system blocks the safe for five