background image

1. Press the EIN/ON key.

2. Key-in the 9-figure mastercode. If you have selected an opening delay of 0 minutes, proceed with step 4.

3. Press the ENTER key once and wait for the opening delay to lapse. Following that, press the ENTER key once more

whilst the short, high-piched signal tones are sounding. Now enter your mastercode once more.

4. Hold the ENTER key pressed down (6 seconds), until you hear a long, high-pitched signal tone.

5. Enter "0" if you want to change the mastercode (9 figures) or any number between 1 and 9, if you want to change

a standard code.

6. Press the ENTER key.

7. Now key in your new code (6 to 8 figures for a new standard code, or 9 figures for a new mastercode).

8. Press ENTER key.

9. Key in the new code once more.

10. Press ENTER key.  If you have performed the coding process correctly, you will hear 2 long, high-pitched signal

tones.

The sounding of two long, low-pitched tones indicates that you made a mistake entering the numerical code.  Please

start over at 1.

TEST - TO BE CARRIED OUT WITHOUT FAIL!

It should not be possible to turn the lock handle half a turn with the door open and

blocked. Press the EIN/ON key, key-in the new numerical code and press the ENTER

key. It should now be possible to open the lock by turning the lock handle half a turn.

DELETING A STANDARD CODE

Proceed exactly as indicated under "programming a numerical code by means of the mastercode" until step 6. Instead of

keying in the new numerical standard code, enter the figure "0" ten (10) times in a row, complete by pressing the ENTER

key. The previously selected combination is now cleared and a new combination can only be coded by means of the

mastercode.

CHANGING A NUMERICAL STANDARD CODE

WHEN CHANGING A NUMERICAL CODE MAKE SURE THE DOOR IS OPEN AND BLOCKED: DO NOT

ENTER PERSONAL DATA (such as your birthday).

If the set numerical code is lost, it is only possible to open the safe or strongroom by using the mastercode or another valid

standard code. Therefore:

DO NOT FORGET THE NEW NUMERICAL CODE; KEEP IT IN A SAFE PLACE!!

1. Press the EIN/ON key.

2. Key-in the old numerical code.  If you have selected an opening delay of 0 minutes, proceed with step 4.

3. Press the ENTER key once and wait for the opening delay to lapse. Following that, press the ENTER key once more

whilst the short, high-piched signal tones are sounding. Now enter your old numerical code once more.

4. Hold the ENTER key pressed down (6 seconds), until you hear a long, high-pitched signal tone.

5. Enter 1 (or 2, 3 ... 9) if you hold the first (or second, third, ... ninth) combination.

6. Press ENTER key.

7. Now key-in your new combination of 6 to 8 figures (e.g. 2 4 7 3 5 8).

8. Press ENTER key.

-- page 3 --

Summary of Contents for E4000R

Page 1: ...dicates that you entered the wrong code If the opening delay is set to 0 zero minutes factory setting please proceed with step 6 4 Wait for the set opening delay to lapse During the waiting time the safe cannot be opened The end of the opening delay is indicated by short high pitched signal tones lasting 30 seconds 5 Press ENTER key before the sounding of the signal tones ceases and re enter the v...

Page 2: ...d tones 1 x short EIN ON key pressed or bolt mechanism unblocked 2 x short End of blocked status 1 x long ENTER key pressed for six seconds start of coding mode 2 x long Coding process completed correctly Low pitched tones 1 x short The entered code is wrong 2 x short EIN ON key pressed while blocked 1 x long This signal sounds after entering the correct numerical code after the lock has been mani...

Page 3: ...the lock by turning the lock handle half a turn DELETING A STANDARD CODE Proceed exactly as indicated under programming a numerical code by means of the mastercode until step 6 Instead of keying in the new numerical standard code enter the figure 0 ten 10 times in a row complete by pressing the ENTER key The previously selected combination is now cleared and a new combination can only be coded by ...

Page 4: ...once and wait for the opening delay to lapse Following that press the ENTER key once more whilst the short high pitched signal tones are sounding Now enter your mastercode once more 4 Hold the ENTER key pressed down 6 seconds until you hear a long high pitched signal tone 5 Enter the 0 6 Press ENTER key 7 Key in the two figure number 60 8 Press ENTER key 9 Enter the new opening delay of your choic...