background image

Made in Germany

www.secu-gmbh.de

Attention

: When saving a fingerprint it is important that the finger is laid 

evenly and in a straight position over the sensor. Follow the instructions on the 
display. The finger is saved only when it can be read in an optimum quality. 

6. Opening with fingerprint*: 

• Press the  On/Enter  key 
• The indication of  Code/Fingerp  is displayed 
• Move the saved finger over the sensor 
• Value not achieved  is displayed
• The  Code/Fingers   indication is displayed  
• At this point, enter an additional opening code (not Fingerprint with   

electronic SELO-BFE 

2

). 

• The instruction  Please turn knob  is displayed 

In case following message is displayed:  Value not achieved , an additional 
opening code shall be entered. (When the programming is made using the 
software only. When programming using the safe electronics, the indication 
Please use rotating knob is displayed already when the second opening code 
has been entered.) 

7. Deleting a finger*: 

• Press the  On/Enter  key 
• The indication of  Code/Fingers**  is displayed 
• Press the  Function  key 
• The  Change code menu  is displayed 
• By pressing the key  2  reach the  Administrator  menu 
• Press the  On/Enter  key 
• Admin setup Create user  is displayed 
• By pressing the key  2  reach the  Admin. setup Delete  menu 
• Press the  On/Enter  key 
• Delete user  is displayed 
• Press the  On/Enter  key 
• At this point you are asked to enter the admin. code (factory setting 

123456) 

• Now you have to select the appropriate user by pressing the keys  1  

or  2

• Press the  On/Enter  key 
• The indication of  Delete data to be confirmed with the On key  is 

displayed. 

• Press the  On/Enter  key 
• The indication of  Data record deleted  is displayed 

Additional users can be deleted using the  On/Enter  key. By pressing the  
Function  key, you can reach higher menu levels up to the code entry. 

SELO-B 

2

SELO-BF 

2

SELO-BFE 

2

5

1.4   Error messages* 

The following error messages are indicated when a finger is being saved or 
the safe opened: 

Error message

Elimination of causes

too fast! please repeat

Move the finger more slowly 
over the sensor

too aslant! please repeat

Move the finger straight over 
the sensor be read 

too short! please repeat

Move the finger over the 
sensor in a way allowing more 
surface area to 

place to the center and repeat!

Place your finger centrally 
over the sensor

Summary of Contents for SELO-B 2

Page 1: ...SELO B 2 SELO BF 2 SELO BFE 2 1 Electronic lock ...

Page 2: ...st must be therefore entered for the opening a value of 1 can be also achieved with an additional fingerscan Attention The values can be adjusted only using additional software When the programming is made on the safe faceplate the pin code and the E Key are automatically assigned the value of 1 the fingerscan receives the value of Attention For security reasons as related to programming using the...

Page 3: ...izations They include Create User Users can be created here A user has either a code or an E Key or both A separate user is always created for a fingerscan Anatomically there are people the fingerprints of whom are not sufficiently articulated for the system SELO B 2 SELO BF 2 SELO BFE 2 3 Assign E Key An E Key can be additionally assigned to a selected user here Delete Users and E Keys can be del...

Page 4: ...F 2 SELO BFE 2 4 If a user with a value of 1 right to open alone should be created the message FS combination to be confirmed with ENTER must be followed by pressing the Function key If the user should be assigned access in combination with a fingerscan only this inquiry is to be confirmed with ENTER 4 Creating a user with an E Key Press the On Enter key The indication of Code Fingers is displayed...

Page 5: ...ey The Change code menu is displayed By pressing the key 2 reach the Administrator menu Press the On Enter key Admin setup Create user is displayed By pressing the key 2 reach the Admin setup Delete menu Press the On Enter key Delete user is displayed Press the On Enter key At this point you are asked to enter the admin code factory setting 123456 Now you have to select the appropriate user by pre...

Page 6: ...Made in Germany www secu gmbh de SELO B 2 SELO BF 2 SELO BFE 2 6 1 5 Menu structure ...

Page 7: ...ies The lock can only be unblocked a further approximately 50 times Please note that none of the number codes can be changed until a set of fresh batteries has been fitted To change the batteries lift off the cover of the battery compartment with the tip of a screwdriver Fit three leak proof type Mignon LR6 AA alkaline batteries paying attention to the correct polarity Dispose of the old batteries...

Page 8: ... Meinerzhagen Germany www secu gmbh de mail secu gmbh de Irrtum und Änderungen vorbehalten Omissions and changes reserved Sous réserve de fautes d erreurs et de modifications BA SELO B 2 SELO BF 2 and SELO BFE 2 MD 07 2011 SECU Sicherheitsprodukte GmbH SELO B 2 SELO BF 2 SELO BFE 2 8 ...

Reviews: