22
FLUSH MOUNT WITH 5S BOX (See Figure 16)
1.
Use the wall cutout template provided. Locate template on the wall.
Transfer appropriate cutout corner locations to the wall with a pointed
instrument.
2.
Draw lines from point to point, outlining cutout.
3.
Cut out opening, being careful not to make opening larger than indicated
on the template.
4.
Place mounting plate against wall in its proper location. Using it as a
template, mark four holes in corners. Remove faceplate, and using
appropriate drill, drill four holes for appropriate fasteners (8-32 fasteners
are recommended).
5.
Fasten mounting plate to 5S box using the four 8-32 flat head screws
provided. (When running wires to the 5S box, don’t use the center top
hole as it will interfere with the housing lock.)
6.
Secure mounting plate and 5S box to wall. Screws must be flat head
countersunk #6 or #8. Make sure any cables have been pulled into the
box prior to securing assembly to wall. For an outdoor installation,
silicone sealant is recommended between the mounting plate and the
wall.
7.
Connect green grounding screw on mounting plate to Earth ground
using a 16AWG wire. Also connect green ground wire from faceplate
assembly to green grounding screw.