C-2
13.
Change the baud rate to match the SK-ACP or 28SA-PLUS. The
default baud rate for these products with firmware version 2.40 or
later is 38,400. (Older products had a default of 9600.)
14.
Accept the other default settings.
15.
Enter “9” to save the settings and exit.
Install the SK-LAN in the field. Connect the Gateway panel or reader to the
DB25 serial output using the provided cable. Connect the 10BASE-T
port to a network jack with an Ethernet cable. Connect the included
power supply to 110VAC.
DO NOT:
•
Plug the Ethernet cable into a telephone jack.
•
Substitute another power supply.
•
Mount the unit in a wet location or a location where temperatures
may exceed 120 degree F.
Test the unit.
1. Ping.
Go to “Start” / “Run”.
Type “command”.Click OK. (This brings up a command prompt.)
Type “ping <IP address> . Press “Enter”.
If the reply indicates “Request Timeouts” there is an error in the setup
or connections.
If the reply shows “Packets sent” and “0% Loss”. The setup and
connections are good.
2. Communicate with SK-LAN.
Go to “Start” / “Run”.
Type “telnet <IP address> 9999. Click OK.
The setup menu of the SK-LAN should appear. Exit