ProLogic L01-C
Operation Instructions
18
Note: The pairing of the StrikeBolt and the ProLogic L01-C EntryPad is not UL listed.
If the lock body that you are pairing the ProLogic L01-C with has been paired previously with an analog
system, for example the SafeLogic Basic (or any other SafeLogic Series EntryPad)or was set at the factory
in the default Analog mode, the following Mechanical Reset procedure must be followed:
Step 1: Ensure that the EntryPad is not connected to the lock, and that the battery is connected
to the EntryPad.
Step 2: Find the reset hole on the back of the lock (under the QC sticker).
Step 3: Using a poke tool, depress the reset button on the back of the lock 3 times. This
discharges any latent energy within the lock’s capacitors.
Step 4: Depress the reset button and hold it in its depressed position. While the reset button is
depressed, connect the cable to the lock.
Step 5: Continue to hold the reset button in its depressed position for another 5 seconds, then
release.
A communication signal has now been sent to the Lock body telling it to convert from analog to
digital mode. The ProLogic will now be able to operate the lock body.
Q: How do you know if the lock has been reset?
•
The ProLogic will not sound or beep when it resets. When a button is pressed, the LCD
will report “Link with Lock OK”. This indicates that the lock is now in digital mode and
has been successfully paired and the default codes will operate the lock. If the LCD
reports “Fail to Link with Lock”, repeat the reset process.
8.0 Testing
The ProLogic L01-C has an onboard system test called “Cycle Testing”
This is a very unique feature to SecuRam safe lock systems. As the access system on a fortified steel
box – the safe -- it is imperative that safe locks can provide solid performance. SecuRam offers this
unique menu selection that allows you to test the lock system performance through actual Cycle
Testing.
8.1 Cycle Testing
In order to perform a cycle test on the ProLogic system, follow these steps: