ProLogic L22
Operation Instructions
37
The ProLogic L22 is a digital system and can be paired with any SecuRam safe lock body.
Note: The pairing of the StrikeBolt and the ProLogic L22 EntryPad is not UL listed.
If the lock body that you are pairing the ProLogic L22 with has been paired previously with an analog
system, for example the SafeLogic Basic (or any other SafeLogic Series EntryPad)or was set at the factory
in the default Analog mode, the following Mechanical Reset procedure must be followed:
Step 1: Ensure that the EntryPad is not connected to the lock, and that the battery is connected
to the EntryPad.
Step 2: Find the reset hole on the back of the lock (under the QC sticker).
Step 3: Using a poke tool, depress the reset button on the back of the lock 3 times. This
discharges any latent energy within the lock’s capacitors.
Step 4: Depress the reset button and hold it in its depressed position. While the reset button is
depressed, connect the cable to the lock.
Step 5: Continue to hold the reset button in its depressed position for another 5 seconds, then
release.
A communication signal has now been sent to the Lock body telling it to convert from analog to
digital mode. The ProLogic will now be able to operate the lock body.