ProLogic L22
Operation Instructions
38
Q: How do you know if the lock has been reset?
•
The ProLogic will not sound or beep when it resets. When a button is pressed, the LCD
will report “Link with Lock OK”. This indicates that the lock is now in digital mode and
has been successfully paired and the default codes will operate the lock. If the LCD
reports “Fail to Link with Lock”, repeat the reset process.
•
16.0 Testing
The ProLogic L22 has 2 onboard system tests:
1) Cycle Testing
2) Hardware Testing
This is a very unique feature to SecuRam safe lock systems. As the access system on a fortified steel
box – the safe -- it is imperative that safe locks can provide solid performance. SecuRam offers this
unique menu selection that allows you to test the lock system performance through actual Cycle
Testing.
The “Hardware Testing” menu selection is not available for field use. It is however used in the
manufacturing process to check the board level components.
16.1 Cycle Testing
In order to perform a cycle test on the ProLogic system, follow these steps:
Step1: Press the Menu/OK button.
Step 2: Using the
and
, scroll to the System Menu and Press OK.
Step 3: The display will prompt you to enter a valid code. Enter either the Super Code (ID00) or
the Manager Code (ID01 or ID02). The “Select Menu” message will be displayed as follows:
Step 4: Scroll
to the menu selection “Cycle testing” and Press OK.
Step 5: The system will prompt you to enter the Manufacture Code. Enter 975246 (PW L
6/Users 10 or PW L 6/Users 30) or 97524600 (PW L 8/Users 30) and press OK.