Model 2100 and 3200 Appliances
181
8240 Controller Card Technical Specifications, continued
Input Current (3200)
1 board set: 650mA, 2 board sets: 950mA, 3 board sets: 1.250A,
4 board sets: 1.550A
Heat Output (2100)
196.2 BTU/hr typical
Heat Output (3200)
1 board set: 255.1 BTU/hr typical, 2 board sets: 372.8 BTU/hr typical,
3 board sets: 490.5 BTU/hr typical, 4 board sets: 608.2 BTU/hr typical
Fuse (AC)
3A, 250V
Connection (AC)
IEC Connector
DC Input (3200 only)
-36 to -72 VDC
DC Input Current
1 board set: 1.100A, 2 board sets: 1.450A, 3 board sets: 2.100A,
4 board sets: 2.750A
DC Heat Output
1 board set: 180.1 BTU/hr typical, 2 board sets: 237.5 BTU/hr typical,
3 board sets: 344.0 BTU/hr typical, 4 board sets: 450.4 BTU/hr typical
Fuse (DC)
8A, 250V
Connection (DC)
screw lug terminals
Power Supply
Dual redundant hot-swappable
Dimensions (2100)
1.75‖ H x 17.5‖ W x 12‖ D
Dimensions (3200)
3.5‖ H x 17.5‖ W x 12‖ D
Weight (2100)
10 lbs.
Weight (3200 AC)
1 board set: 19 lbs, 2 board sets: 20 lbs, 3 board sets: 21 lbs,
4 board sets: 22 lbs
Weight (3200 DC)
1 board set: 19 lbs, 2 board sets: 20 lbs, 3 board sets: 21 lbs,
4 board sets: 22 lbs
Mounting
Desktop, 19‖ Rack, or Wall-Mount
Operating Temperature
32 to 104 F (0 to 40 C)
Storage Temperature
-4 to 158 F (-20 C to +70 C)
Fans
3 fans on a removable fan tray (3200)
Number of Lines
Up to 4 (2100) or 16 (3200) T1, North American ISDN PRI, or
European ISDN PRI Circuits
Line Rate
1.544 or 2.048 Mbps
Line Framing
SF (D4), ESF, CRC 4
Line Code
AMI, B8ZS, HDB3
Input Signal
0 to -36 dB