Installing the NFPA label
NOTE: Each DEM680E comes with an NFPA exit
delay door label as required by fire code.
1
FOLLOW the included application instructions
to apply the lettering to a door.
Restoring factory
default settings
1
DISCONNECT power from the Magnalock.
2
REMOVE the cover using a Phillips screwdriver.
3
SET DIP-switch 10 (SW 10) to “ON” (see
Diagram 40
).
NOTE:
When power is applied with SW 10 in the ON
position, previous calibration settings are erased. The LED
will continue to flash red until SW 10 is switched OFF.
4
APPLY power to the Magnalock and
verify that the LED flashes red.
5
SET SW 10 to OFF. The unit should auto-calibrate.
If the unit fails to calibrate see
Troubleshooting
Guide
, or contact technical support.
Diagram 40 Setting DIP-switch 10 to ON
Dip Switch 10 – ON