Installing the NFPA label

NOTE: Each DEM680E comes with an NFPA exit 

delay door label as required by fire code. 

FOLLOW the included application instructions 

to apply the lettering to a door.

Restoring factory 

default settings

DISCONNECT power from the Magnalock.

REMOVE the cover using a Phillips screwdriver.

SET DIP-switch 10 (SW 10) to “ON” (see 

Diagram 40

).

NOTE:

  When power is applied with SW 10 in the ON 

position, previous calibration settings are erased. The LED 

will continue to flash red until SW 10 is  switched OFF.

APPLY power to the Magnalock and 

verify that the LED flashes red.

SET SW 10 to OFF. The unit should auto-calibrate. 

If the unit fails to calibrate see 

Troubleshooting 

Guide

, or contact technical support.

Diagram 40  Setting DIP-switch 10 to ON

Dip Switch 10 – ON

Summary of Contents for ASSA ABLOY Magnalock DEM680E Series

Page 1: ...ns Dimensions Height 2 50 64 mm Depth 2 56 65 mm Length 11 50 292 mm Certifications UL 10C Fire Rated 1 Hour CAN ULC S104 Fire Door Conformant UL 294 UL Tested Ratings Endurance 100 000 cycles ANSI BH...

Page 2: ...needed on one or both sides of the bracket see Diagram 9 4 REMOVE the protective tape from the frame 5 Temporarily INSTALL the mounting bracket with template pins against the closed door using a Phill...

Page 3: ...IGHTEN the screw into the sex bolt using the 3 16 hex wrench While tightening gently tap the head of the sex bolt using a rubber mallet until the head sits flush with the door NOTE To provide maximum...

Page 4: ...dooropens Normally open 2 3 Normally closed NC Normallyclosedcircuit openswhendooropens JP3 EXT INIT 1 2 Disabled Whenenabled allowsunitto beinitiatedfromanexternal source J1 Terminal4 Disabled 2 3 En...

Page 5: ...PERFORM amanualcalibrationimmediately followinginstallation ifnecessary 1 ENSURE that the door is closed 2 APPLY power to the Magnalock 3 PRESS AND RELEASE the calibration button see Diagram 34 4 VER...

Page 6: ...ld turn red and the door should freely open see Diagram 39 After testing close the door and perform a reset After reset the strobe should turn off and the LED should change from red to green VERIFICAT...

Page 7: ...E Each DEM680E comes with an NFPA exit delay door label as required by fire code 1 FOLLOW the included application instructions to apply the lettering to a door Restoring factory defaultsettings 1 DIS...