background image

 

500-10420, Rev G

 

Figure 3.  Magnalock Installation on an In-Swinging Door 

 

INSTALLING A MAGNALOCK 

Attach the Template and Mark the Drill Holes 

1.  SELECT a mounting location for the Magnalock and strike assembly. 

NOTE:

 

The edge of the template should be about 1” (25.4 mm) from the latch 
side of the door to allow proper access at the mounting locations for 
drilling and tool access. 

2.  ATTACH the template to the 

door and frame as shown in 
Figure 4, “Attaching the 
Template.” 

Figure 4.  Attaching the Template 

 

a. 

IF

 Installing a strike 

plate horizontally, 

THEN

 ENSURE the top 

edge of the strike will be 
approximately 
1/8" [3.2 mm] below the 
door frame stop. 

b. 

IF

 the strike and magnet are to be mounted vertically, 

THEN

 INCREASE the clearance between the strike and frame to 

3/16" [4.8 mm]. 

3. 

WHEN

 the template is 

attached, 

THEN

 MARK the location of 

all holes to be drilled using a 
center punch (see Figure 5, 
“Marking Drill Hole 
Locations”).

 

Figure 5.  Marking Drill Hole Locations 

 

Summary of Contents for Magnalock M32

Page 1: ...0 Rev G Magnalock Models M32 M62 and M82B Installation and Operating Instructions 10027 S 51st St Ste 102 Phoenix AZ 85044 Tel 1 800 624 5625 Mon Fri 6 00am 4 00pm PDT securitron com techsupport secur...

Page 2: ...h the Template and Mark the Drill Holes 6 Drill the Holes for the Lock Body and Strike Plate 7 Install the Blind Nuts 8 Install the Strike Plate 9 Install the Magnalock 12 Wire Double Door Status 15 W...

Page 3: ...sor is activated by a special magnetic strike armature assembly This isolated SPDT reed switch with an internal resettable protection device is designed for interface to access control and or alarm sy...

Page 4: ...en end or Crescent Wrench Perform a Pre Installation Survey NOTE 1 Additional brackets may be needed for proper installation Specialized brackets are available through Securitron and its many product...

Page 5: ...5 500 10420 Rev G Accessibility for prevention of potential safety hazards Figure 2 Magnalock Installation on an Out Swinging Door...

Page 6: ...2 ATTACH the template to the door and frame as shown in Figure 4 Attaching the Template Figure 4 Attaching the Template a IF Installing a strike plate horizontally THEN ENSURE the top edge of the str...

Page 7: ...the way through the door 1 DRILL the three holes for the installation of the strike plate Figure 6 Installation Drill Holes NOTE 1 Figure 7 Lock Body Drill Holes provides illustration for the followi...

Page 8: ...Nut Components Figure 9 Installing the Blind Nuts and Figure 10 Blind Nut Before and After Collapse provide illustration for the steps in this section Figure 8 Blind Nut Components Figure 9 Installing...

Page 9: ...allations c REMOVE the collapsing tool when finished NOTE Once installed the blind nuts leave a threaded insert that will accept the case hardened machine screws provided in the hardware pack d VERIFY...

Page 10: ...Figure 14 Strike Plate Assembly provides illustration for the Steps 4 6 Figure 14 Strike Plate Assembly 4 INSERT the 5 16 18 bolt through the funnel bushing and strike plate NOTE It may be necessary t...

Page 11: ...the door gently TAP the sex bolt into place see Figure 15 Installing the Sex Bolt NOTE The center screw should not be over tightened strike should float Figure 16 Installing the Strike Plate 8 INSTAL...

Page 12: ...ate must be in proper alignment or the BondSTAT and DPS functions will not operate correctly NOTE 1 When installing the Magnalock and strike plate each should be in proper alignment to the other see F...

Page 13: ...DC output of the power supply must not be connected to earth ground but must be isolated or possible damage to the product could result NOTE In order to confirm that the DC outputs of a power supply a...

Page 14: ...wires supply electrical connection when the lock OFF or unsecure Figure 21 Connections for BondSTAT B Version NOTE 1 In Figure 22 the blue and yellow wires supply electrical connection when the door c...

Page 15: ...one lock to the white wire of the other as shown in Figure 24 Double Door Status Wiring Figure 24 Double Door Status Wiring Wire Double Door Status DPS NOTE When two Magnalocks are used for double do...

Page 16: ...strike armature CLEAN as required 3 CHECK for rust on the Magnalock and strike plate armature CLEAN as required Clean the Magnalock 1 CLEAN the Magnalock at the following intervals Once a year for nor...

Page 17: ...or specified voltage at Magnalock Check for specified current draw at Magnalock CHECK strike mounting for proper alignment and pivoting for proper closure to Magnalock CHECK the Magnalock and strike f...

Page 18: ...ance on the source Using the correct gauge wires protects against large voltage and current load losses The gauge is determined by the wire distance voltage and current of all devices 1 CALCULATE tota...

Page 19: ...16 Gauge 14 Gauge 14 Gauge 20A 24 Gauge 22 Gauge 22 Gauge 22 Gauge 20 Gauge 18 Gauge 18 Gauge 16 Gauge 14 Gauge 12 VDC 50 15m 100 30m 150 46m 200 61m 300 91m 400 122m 500 152m 750 229m 1000 305m WIRE...

Page 20: ...gistration is required Product will be replaced forever for any reason including but not limited to installation error vandalism or acts of God Replacement product is shipped at Securitron s expense n...

Reviews: