INSTALLATION STEP 12

Connect the Door Arm to the Trolley

Follow instructions which apply to your door type as
illustrated below and on the following page.

SECTIONAL DOORS ONLY

• Make sure garage door is fully closed. Pull the

emergency release handle to disconnect the outer
trolley from the inner trolley. Slide the outer trolley
back (away from the door) about 2" (5 cm) as
shown in Figures 1, 2 and 3.

• Figure 1:

– Fasten straight door arm section to outer trolley

with the 5/16"x1" clevis pin. Secure the
connection with a ring fastener.

– Fasten curved section to the door bracket in the

same way, using the 5/16"x1-1/4" clevis pin.

• Figure 2:

– Bring arm sections together. Find two pairs of

holes that line up and join sections. Select holes
as far apart as possible to increase door arm
rigidity.

• Figure 3, Hole alignment alternative:

– If holes in curved arm are above holes in straight

arm, disconnect straight arm. Cut about 6" 
(15 cm) from the solid end. Reconnect to trolley
with cut end down as shown.

– Bring arm sections together.

– Find two pairs of holes that line up and join with

bolts, lock washers and nuts.

• Pull the emergency release handle toward the

opener at a 45° angle so that the trolley release
arm is horizontal. Proceed to Adjustment Step 1,
page 23. Trolley will re-engage automatically when
opener is operated.

Ring 
Fastener

Door
Bracket

Cle

v

is Pin

5/16"x1-1/4"

C

u

r

v

ed

Door Arm

Straight
Door Arm

Cle

v

is Pin

5/16"x1"

Inner Trolley

O

u

ter Trolley

Lock

W

ashers

5/16"

Nu

ts

5/16"-1

8

Door Bracket

Bolts
5/16"-1

8

x7/

8

"

Emergency
Release
Handle

Lock

W

ashers

5/16"

Nu

ts

5/16"-1

8

Bolts
5/16"-1

8

x7/

8

"

C

u

t This End

Figure 1

Figure 2

Figure 3

Lock 

W

asher 5/16"

Nu

t 5/16"-1

8

Ring Fastener

Hex Bolt
5/16"-1

8

x7/

8

"

Cle

v

is Pin

5/16"x1" (Trolley)

Cle

v

is Pin

5/16"x1-1/4" (Door Bracket)

HARDWARE SHOWN ACTUAL SIZE

Summary of Contents for Elite 3885C

Page 1: ...ease read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connected and properl...

Page 2: ...32 33 To add or reprogram a hand held remote control 32 To erase all codes from motor unit memory 32 3 Button remotes 32 To add reprogram or change a Keyless Entry PIN 33 Repair Parts 34 35 Rail assem...

Page 3: ...arage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or binding 1 Lift the door...

Page 4: ...ou proceed with the installation of your opener Access Door Safety Reversing Sensor Safety Reversing Sensor Gap between floor and bottom of door must not exceed 1 4 6 mm ONE PIECE DOOR WITH TRACK Safe...

Page 5: ...ne Piece Rail Styrofoam Belt Pulley Bracket Belt Trolley SECURITY 3 Button Remote Control The Protector System 2 Safety Reversing Sensors 1 Sending Eye and 1 Receiving Eye with 2 Conductor White White...

Page 6: ...16 92 5 21 92 6 2 92 6 11 92 Nut Ring Trolley Threaded Shaft Nut Ring Slots Square End Nut Ring Trolley Nut Ring Trolley 1 2 5 cm 1 1 4 3 18 cm BEFORE AFTER RELEASE Figure 1 Figure 2 Figure 3 ASSEMBL...

Page 7: ...ms 9 Install wall mounted garage door control within sight of the garage door out of reach of children at minimum height of 5 feet 1 5 m away from ALL moving parts of the door 10 Place entrapment warn...

Page 8: ...the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 9 for ceiling installation To prevent possible SERIOUS INJURY...

Page 9: ...age Door Header Wall Garage Door UP CEILING MOUNT ONLY Wall Mounting Holes Optional Wall Mounting Holes The nail hole is for positioning only You must use lag screws to mount the header bracket UP CEI...

Page 10: ...Bracket Position the opener on the garage floor below the header bracket Use packing material as a protective base NOTE If the door spring is in the way you ll need help Have someone hold the opener...

Page 11: ...g an ideal door to rail distance Remove foam packaging Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way and place a 2x4 la...

Page 12: ...the motor unit to the structural support 2 Cut both pieces of the hanging bracket to required lengths 3 Drill 3 16 pilot holes in the structural supports 4 Attach one end of each bracket to a support...

Page 13: ...snap cover in place 3 For standard installations ONLY Run bell wire up wall and across ceiling to motor unit Use insulated staples to secure wire in several places Do NOT pierce wire with a staple cr...

Page 14: ...trolley Adjust rope length so the handle is 6 feet 1 83 m above the floor Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement Secure with an overhand knot NOTE If it i...

Page 15: ...he black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be grounded Reinstall the...

Page 16: ...ove the floor Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the track of...

Page 17: ...p hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figure 2 3 Place the bracket again...

Page 18: ...th the sending and receiving eyes will glow steadily if wiring connections and alignment are correct The sending eye amber indicator light will glow regardless of alignment or obstruction If the green...

Page 19: ...ollows depending on your door s construction Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket Drill 3 16 fastening holes Secure the doo...

Page 20: ...INUM STEEL DOORS WITH GLASS PANEL ETC NOT PROVIDED ONE PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page They apply to one piece doors also Cente...

Page 21: ...Figure 3 Hole alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown...

Page 22: ...hers 5 16 Ring Fastener Straight Arm Bolts 5 16 18x7 8 Door Bracket Clevis Pin 5 16 x1 1 4 Curved Door Arm Press the Door Control push button The trolley will travel to the fully closed position Manua...

Page 23: ...tment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 3 7 5 cm of travel If door still won t close completely an...

Page 24: ...ke small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount required to close t...

Page 25: ...un the opener through 3 or 4 complete travel cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT SAFETY CHECK Test the...

Page 26: ...ture on the Motion Detecting Control Console is activated Bulb size is A19 Bulb power is 100 watts maximum Security light feature Lights will also turn on when someone walks through the open garage do...

Page 27: ...ll come on for five minutes then shut off This feature works by detecting body heat To disable this feature push the motion sensing button on the side of the door control We recommend that you disable...

Page 28: ...DOWN operation either manually or by using the door control or remote To prevent possible SERIOUS INJURY or DEATH from a falling garage door If possible use emergency release handle to disengage troll...

Page 29: ...his device must accept any interference received including interference that may cause undesired operation MAINTENANCE SCHEDULE Once a Month Manually operate door If it is unbalanced or binding call a...

Page 30: ...justments to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to Adjustment Step 1 Adj...

Page 31: ...touch wires together If motor unit activates replace door control If motor unit does not activate disconnect door control wires from motor unit Momentarily short across red and white terminals with j...

Page 32: ...e Control USING THE LEARN BUTTON TO ADD ADDITIONAL REMOTE CONTROLS USING THE LCD CONTROL CONSOLE LOCK LIGHT LOCK LIGHT PROGRAMMING Your garage door opener has already been programmed at the factory to...

Page 33: ...as set to a certain number of openings remember that the test has used up one opening To clear the temporary password repeat steps 1 3 setting the number of hours or times to 0 in step 3 To Add Reprog...

Page 34: ...ntrol console 2 373LMC 3 button remote control 3 10A20 3V2032 Lithium battery 4 29B137 Remote control visor clip 5 41A2828 Emergency Release rope handle assembly 6 41B4494 1 2 Conductor bell wire whit...

Page 35: ...tor 56uF 8B 30B529 Capacitor 40uF 8C 41A5637 Resistor 9 41A3150 Terminal block w screws 10 41D5563 1 Universal replacement motor bracket assembly Complete with Motor worm bracket gear case bearing ass...

Page 36: ...pen or closed Monitors up to 4 garage doors by adding additional sensor modules 915LMC Garage Door Monitor Sensor Additional accessory sensor for homes with multiple garage doors 916LMC 373LMC 3 Butto...

Page 37: ...37 NOTES...

Page 38: ...38 NOTES...

Page 39: ...39 NOTES...

Page 40: ...T LIMITED TO ABUSE MISUSE FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT REP...

Page 41: ...s consignes de s curit Apr s la pose accrocher ce manuel pr s de la porte de garage pour s y reporter ult rieurement La porte NE SE FERMERA PAS si le Syst me Protector n est pas branch et r gl correct...

Page 42: ...r ou reprogrammer une t l commande main suppl mentaire 32 Pour effacer tous les codes de la m moire de moteur 32 T l commandes trois boutons 32 Pour ajouter reprogrammer ou modifier un NIP d entr e sa...

Page 43: ...les poulies supports de porte ou leurs ferrures de montage lesquels sont TOUS sous une tension EXTR ME D sactiver TOUTES les serrures et retirer TOUTES les cordes raccord es la porte de garage AVANT d...

Page 44: ...e de l ouvre porte Porte d acc s L espace entre le plancher et le bas de la porte ne doit pas tre sup rieur 1 4 po 6 mm D tecteur inverseur de s curit D tecteur inverseur de s curit PORTE RIGIDE AVEC...

Page 45: ...ion et 1 il de r ception avec fil de sonnerie blanc et blanc noir deux conducteurs fix SECURITY T l commande trois boutons Console de commande ACL de porte avec d tection de mouvement Moteur avec diff...

Page 46: ...sus du pignon du moteur Pour viter des dommages S RIEUX l ouvre porte utiliser UNIQUEMENT les boulons et les fixations mont s sur le dessus du moteur ATTENTION AVERTISSEMENT N UTILISER QUE CE TYPE ET...

Page 47: ...e TOUTES les pi ces mobiles de la porte 10 Placer l tiquette d avertissement de prise au pi ge sur le mur c t de la commande de la porte de garage 11 Placer l tiquette d essai d inversion de s curit o...

Page 48: ...orte REMARQUE Si le nombre total de pouces centim tres d passe la hauteur disponible dans le garage utiliser la hauteur maximum ou se reporter la page 9 pour la pose au plafond Porte articul e avec gu...

Page 49: ...Porte de garage Trous de fixation au mur Trous de fixation au mur en option Le trou du clou n est pr vu que pour le positionnement seulement Des tire fond doivent tre utilis s pour fixer le support d...

Page 50: ...port de linteau Utiliser une des bo tes d emballage pour le prot ger REMARQUE Si le ressort de la porte g ne il faudra demander de l aide Demander une personne de bien retenir l ouvre porte sur un sup...

Page 51: ...Enlever l emballage en mousse Lever l ouvre porte et le faire reposer sur un escabeau Si l escabeau n est pas assez haut demander de l aide Ouvrir compl tement la porte et mettre un 2 x 4 plat sur sa...

Page 52: ...l ouvre porte et les solives 2 Couper les deux supports de suspension la longueur requise 3 Percer des avant trous de 3 16 pouce dans les solives 4 Fixer une extr mit de chaque support de suspension s...

Page 53: ...er 7 16 po 11 mm d isolation de l extr mit du fil de sonnerie Raccorder le fil de sonnerie aux bornes raccordement rapide comme suit le fil blanc blanc et le fil blanc rouge rouge Figure 3 REMARQUE En...

Page 54: ...nviron 6 pieds 1 83 m du sol S assurer que la corde et la poign e ne risquent pas de toucher au capot d aucun v hicule pour viter qu elle s emm le Fixer la corde l aide d un n ud simple REMARQUE Si la...

Page 55: ...re porte pour le moment Afin de minimiser les risques de chocs lectriques le cordon d alimentation de l ouvre porte de garage comporte une fiche trois broches dont une de mise la terre Cette fiche ne...

Page 56: ...ceptrice Les supports de montage sont con us en vue de leur fixation par pince sur le guide des portes de garage articul es sans fixations suppl mentaires Si les unit s doivent tre mont es sur le mur...

Page 57: ...ur l aide de tire fond Non fournis Si des supports de rallonge ou des blocs de bois sont employ s ajuster les ensembles droit et gauche la m me distance vers l ext rieur depuis la surface de montage S...

Page 58: ...AGE ET C BLAGE DES D TECTEURS INVERSEURS DE SECURIT Faire glisser un boulon t te bomb e et collet carr de 1 4 po 20 x 1 2 po dans la fente de chaque d tecteur Utiliser des crous oreilles pour fixer le...

Page 59: ...galement utiliser deux boulons de 5 16 po des rondelles de blocage et des crous non fournis Figure 2B Portes m talliques isol es ou l g res renforc es l usine Percer des trous de fixation de 3 16 po F...

Page 60: ...NEAUX DEVERRE ETC NON FOURNIS Vis autotaraudeuse 1 4 de po 14 x 5 8 de po GRANDEUR R ELLE DES FIXATIONS PORTES RIGIDES Pri re de lire et de suivre les avertissements et les instructions de renforcemen...

Page 61: ...o 15 cm du bout Refixer la biellette droite sur le chariot en orientant la partie coup e vers le bas comme illustr Rapprocher les biellettes Aligner deux paires de trous et raccorder les deux biellett...

Page 62: ...illustration Si la biellette est trop courte diminuer la course d ouverture Un tour complet de la vis de r glage correspond 3 pouces 7 5 cm de course R glage de la fermeture de la porte diminuer la co...

Page 63: ...rse de fermeture en tournant la vis de r glage DOWN dans le sens antihoraire Un tour complet de la vis correspond 3 po 7 5 cm de course Si la porte ne se ferme toujours pas compl tement et que le char...

Page 64: ...arr ter la main La porte doit remonter L inversion du mouvement de fermeture de la porte mi chemin ne garantit pas l inversion lorsqu il s agit d une obstacle de 1 1 2 po 3 8 cm Se reporter la 3e op r...

Page 65: ...r un technicien form en syst mes de porte V RIFICATION DE S CURIT IMPORTANTE Faire l essai du syst me d inversion de s curit apr s Chaque fois que l on modifie la longueur des biellettes et chaque foi...

Page 66: ...lumi res s allumeront galement lorsqu une personne franchira la porte de garage ouverte Sur la Console de commande de porte de d tection de mouvement cette fonction d clairage peut tre d sactiv e de...

Page 67: ...ucun diff rentiel de chaleur n est d tect Prog Learn Heure Minute Langue Degr s F C Bouton d clairage Bouton de verrouillage Barre poussoir D tecteur de mouvement actv e d sactiv e LOCK LIGHT PROG Fon...

Page 68: ...LESSURES GRAVES ou LA MORT par suite de la chute d une porte de garage Si possible utiliser la poign e de d clenchement d urgence pour d gager le chariot UNIQUEMENT lorsque la porte de garage est FERM...

Page 69: ...les charni res de la porte Il n est pas n cessaire de lubrifier l ouvre porte de garage Ne pas graisser les guides de la porte AVIS Les r gles de la FCC ou d Industrie Canada IC ou les deux interdise...

Page 70: ...r le de l inversion de s curit apr s avoir proc d au r glage de la force ou des limites de course Le besoin de proc der des r glages occasionnels des limites de courses et de la force est normal Les v...

Page 71: ...agrafe dans le fil remplacer si n cessaire D connecter les fils au niveau de la commande de porte toucher les fils l un l autre Si le moteur se met en marche remplacer la commande de porte Si le mote...

Page 72: ...el cher le bouton learn sur le moteur Le t moin lumineux learn s allumera en continu pendant 30 secondes 2 Dans un d lai de 30 secondes enfoncer et tenir le bouton de la t l commande qui fera fonction...

Page 73: ...duisant sur le nouveau NIP puis appuyer sur ENTER La porte devrait bouger Pour d finir un NIP temporaire Vous pouvez autoriser l acc s aux visiteurs ou aux techniciens de service l aide d un NIP tempo...

Page 74: ...10A20 Pile au lithium 3V2032 4 29B137 Agrafe de pare soleil de la t l commande 5 41A2828 Poign e et corde pour fonctionnement d urgence 6 41B4494 1 Fil de sonnerie blanc et blanc rouge 2 conducteurs...

Page 75: ...ouille d ampoule 7 108D79 Diffuseur 8A 30B530 Capacitor 56uF 8B 30B529 Capacitor 40uF 8C 41A5637 Resistor 9 41A3150 Bornier vis 10 41D5563 1 Moteur de rechange universel et support Comprend Moteur vis...

Page 76: ...onction pour 2 et 3 portes Id al pour les domiciles qui comptent jusqu trois portes Trois postes de commande log s dans un m me panneau pour garder une apparence propre et d gag e Fonction de verrouil...

Page 77: ...37 REMARQUES...

Page 78: ...38 REMARQUES...

Page 79: ...39 REMARQUES...

Page 80: ...ront r par s ou remplac s la seule discr tion du Vendeur sans frais pour l acheteur puis retourn s en port pay Les pi ces d fectueuses seront r par es ou remplac es par de nouvelles pi ces ou des pi c...

Reviews: