20
Exception #2:
For the single outlet, the framing must be 8 _" x 32 _" (210 mm x 820
mm) or as required by the integrated spacers. At no time should any combustible facing
material such as panelling cover over any part of the grill face.
3.
The maximum number of elbows in a run of duct is two.
4.
Maintain at least 6 _" (160 mm) clearance from the outlet grill framing to a combustible
ceiling, side wall or mantel.
5.
When traversing a combustible wall or floor, a fire stop must be installed at the wall or floor
penetration. The hole size must be 13" X 13". (330 mm x 330 mm)
6.
Do not connect the hot air ducts to a central heating system. Malfunction of the heating
system’s fan will cause the fireplace to overheat. A furnace duct is only single wall and not
double wall as is required for the BIS ULTRA hot air exhaust
7.
Use only Security Chimneys International grills and components as described in this manual.
Other grills or registers, for example, may be too restrictive and may overheat the fireplace or
ceiling.
8.
Do not use insulated flexible ducts, as they may overheat.
9.
Do not use tees or any other components than the ones specifically listed here.
10.
All ducts must extend upwards or horizontally. Never try to route the ducting downward.
11.
The hot air outlet grills must be installed with the louvers pointing downwards in order to
prevent overheating adjacent ceilings.
3.5.2 Central Forced Air Kit
(Not tested under EPA certification)
The knock-outs provided on the back and on the sides of the BIS ULTRA allow the
connection of insulated flexible pipe which enables you to heat adjacent rooms up to 50
feet from the fireplace.
The ducting system must be installed as described below:
1.
Fix the adaptor at the back and/or the side of the fireplace by twist-locking the
adaptor to the fireplace. You can use more than one outlet on the fireplace (figure 19).
2.
Attach the 5" flexible pipe, using the collars provided. Important: Make sure that the
plastic wrapping around the flexible pipe will not be in contact with the fireplace.
3.
Route the flexible pipe to the chosen location. The ducting system can be installed
either in an upper room or in a lower room.
4.
Attach the flexible pipe to the fan, using the collars (figure 20).
5.
Fix the decorative grill fan adaptor to the fan.
6.
Attach a standard 3" x 10" grill to the adaptor.
7.
Install the
blower thermostat
in that part of the house to be heated by the hot air duct.
Do not install the
blower thermostat
in the room where the fireplace is located. A
cooling thermostat
can be installed in the same room as the unit. This thermostat will
turn on the blower when the room where the fireplace is located becomes too hot.
This option requires electricity. Make sure that the connections to the fan have been
made according to the local codes and comply with their requirements.
Figure 20
Figure 19
Summary of Contents for EPA BIS ULTRA
Page 2: ...Printed in Canada Rev 9 April 2007 PIBISULTRAEPA ...
Page 7: ...2 2 CERTIFICATION LABEL ...
Page 10: ...5 ...
Page 20: ...15 Figure 7 Figure 9 Figure 8 Figure 10 ...
Page 30: ...25 Figure 28 NOTE THE OUTSIDE AIR KIT IS MANDATORY FOR BOTH FIREPLACE AND CHIMNEY ...
Page 35: ...30 Figure 31 Figure 32 ...
Page 37: ...32 ...