31
4.4
ANGLED WALL RADIATION SHIELD
(
RSM+, RSMI30, RSMI45)
When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled fire
stop or wall radiation shield must be installed. Only one is required.
Note: 45º angle for Canada only
In cold climate locations, we recommend that you use the insulated wall radiation shield
since it will maintain the home’s thermal barrier.
RSM+ and RSMI30, RSMI45
CHIMNEY – 6” dia.
ANGLE
HOLE SIZE
30º
283 mm x 781 mm (11 1/8 " x 30 _ ")
Secure Temp
ASHT+
Nova Temp
45º
Canada
only
283 mm x 518 mm (11 1/8 " x 20 3/8 ")
30º
327 mm x 881 mm (12 7/8" x 34 11/16")
Secure Temp
S2100+
Nova Temp
Ac ( 6" Dia. )
45º
Canada
only
380 mm x 972 mm (15" x 38 _ ")
Table 5
Figure 33