15
A
NGLED
W
ALL
R
ADIATION
S
HIELD
(RSM 30°, RSM 45°)
OR
I
NSULATED
R
ADIATION
S
HIELD
(RSMI 30°, RSMI 45°)
(See Figure #15)
When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop and / or wall radiation
shield must be installed. Only one is required.
NOTE: 45º ANGLE FOR CANADA ONLY.
In cold climate locations (such as Canada and Northern USA), we recommend that you use the insulated wall
radiation shield since it will maintain the home's thermal barrier.
RSM 30°, 45° and RSMI 30°, 45°
CHIMNEY
ANGLE
HOLE SIZE
7" ASHT+ (Canada only)
8" ASHT+ (Canada only)
30°
45°
30°
45°
13 3/8 x 33 ¼
(340 x 845 mm)
13 3/8 x 23 ¼
(340 x 591 mm)
14 3/8 x 36 ½
(365 x 927 mm)
14 3/8 x 24 ¾
(356 x 629 mm)
7" S-2100+ (Canada only)
8" S-2100+ (Canada only)
30°
45°
30°
45°
15 x 38 ¼
(380 x 972 mm)
15 x 25
7
/
8
(380 x 657 mm)
16 x 40
(406 x1016 mm)
16 x 27 ¼
(406 x 692 mm)
7" AC
8" AC
30°
30°
15 x 38 ¼
(380 x 972 mm)
15 x 38 ¼
(380 x 972 mm)
Table 6
Figure 15
DRYWALL
INSULATED
WALL
ANGLE WALL
RADIATION SHIELD
(INSULATED)