Premium Shield Accessories
Radiation Shield Connector (Insulated)
A
24”
Used in conjunction with a radiation shield connector support (RSSR) or firestop
(RCSP) where the enclosed chimney passes through a ceiling/floor. It attaches to the
chimney using 4 screws through brackets. A storm collar must be used at the top in an
attic installation.
ASHT
Ref. SRS
Ø int.
6"
7"
8"
A ext.
10-13/32"
11-13/32"
12-13/32"
Radiation Shield Connector Firestop
A
B
ØC
w
ASHT
Ref. RCSP
Ø int.
6"
7"
8"
A
16"
16"
16"
B
12"
13"
14"
C
10-21/32"
11-21/32"
12-21/32"
Radiation Shield Connector Support
B
ØA
Used in conjunction with a radiation shield connector (SRS) on floors where the
chimney needs to be supported (for example, after an offset).
ASHT
Ref. RSSR
Ø int.
6"
7"
8"
A ext.
10-17/32"
11-17/32"
12-17/32"
B ext.
15"
16"
17"