background image

Offset and rise calculation

The following steps will help determine 

the lengths required for an installation:

1. Determine the offset required in view 

of the obstacles that must be avoided. 

2. Refer to the “Offset/Rise Chart" to 

determine the elbows required as well as 

the insulated lengths needed.

3. Check the corresponding offset height 

dimensions.

ELBOW OFFSET & RISE CHART

One length between elbows

Angle

Dia.

8"

12"

18"

24"

36"

48"

15

6" & 8"

Offset

3-5/16"

4-5/16"

5-7/8"

7-7/16"

10-1/2"

13-5/8"

Rise

16"

19-7/8"

25-11/16"

31-1/2"

43-1/16"

54-5/8"

Two lengths between elbows

8" & 48"

12" & 48"

18" & 48"

24" & 48"

36" & 48"

48" & 48"

Offset

15-1/2"

16-1/2"

18-1/16"

19-5/8"

22-3/4"

25-13/16"

Rise

61-7/16"

65-1/4"

71-1/16"

76-7/8"

88-1/2"

100-1/16"

Angle

Dia.

8"

12"

18"

24"

36"

48"

30

6" & 8"

Offset

7-3/8"

9-3/8"

12-3/8"

15-3/8"

21-3/8"

27-3/8"

Rise

20-11/16"

24-3/16"

29-3/8"

34-9/16"

44-15/16"

55-5/16"

Two lengths between elbows

8" & 48"

12" & 48"

18" & 48"

24" & 48"

36" & 48"

48" & 48"

Offset

30-7/8"

32-7/8"

35-7/8"

38-7/8"

44-7/8"

50-7/8"

Rise

61-3/8"

64-7/8"

70-1/16"

75-1/4"

85-5/8"

96"

Angle

Dia.

8"

12"

18"

24"

36"

48"

45

6" & 8"

Offset

10-5/16"

13-3/16"

17-3/8"

21-5/8"

30-1/8"

38-5/8"

Rise

17-13/16"

20-5/8"

24-7/8"

29-1/8"

37-5/8"

46-1/8"

Two lengths between elbows

8" & 48"

12" & 48"

18" & 48"

24 "& 48"

36" & 48"

48" & 48"

Offset

43-7/16"

46-1/4"

50-1/2"

54-3/4"

63-1/4"

71-11/16"

Rise

50-15/16"

53-3/4"

58"

62-1/4"

70-3/4"

79-3/16"

9

Exterior installation to  

a wood stove.

OFFSET

RISE

INSTALLATION KEY

1

Black Stove Pipe

2

Finishing Cone

3

Insulated Wall Thimble

4

Tee Support

5

Insulated Tee

6

Insulated Length

7

Universal Wall Band

8

Insulated Attic Radiation Shield

9

Adjustable Roof Flashing w/ Storm Collar

10

Rain Cap

11

Firestop

12

Finishing Support

13

Anchor Plate

10

9

8

11

7

6

5
4

3

2

1

3   Security Chimneys   |   www.securitychimneys.com

Summary of Contents for Secure Temp ASHT

Page 1: ...Secure Temp S2100 and ASHT www securitychimneys com 800 361 4909 US 800 667 3387 Canada High Temperature Factory Built Chimneys ...

Page 2: ...OMPOSITION AND EASE OF INSTALLATION The use of stainless steel selected for its resistance to high temperatures and corrosion lends outstanding durability to the Secure Temp S2100 high temperature chimneys Secure Temp S2100 has a temperature rating of 650 C 1200 F max continuous 760 C 1400 F brief forced fired and 1150 C 2100 F 3 x 30 minutes tested All chimneys feature 2 inches S2100 of superior ...

Page 3: ...ildup Increases appliance performance by providing stable draft Low surface temperature Minimum 2 inch safety clearance to combustible materials in all diameters Fast venting of combustion products Delivers a stable and powerful draft Stainless steel outer casing Supports the structural load Corrosion resistance Inner liner attached only to the male coupler Free floating inner wall means no need f...

Page 4: ... 12 3 8 15 3 8 21 3 8 27 3 8 Rise 20 11 16 24 3 16 29 3 8 34 9 16 44 15 16 55 5 16 Two lengths between elbows 8 48 12 48 18 48 24 48 36 48 48 48 Offset 30 7 8 32 7 8 35 7 8 38 7 8 44 7 8 50 7 8 Rise 61 3 8 64 7 8 70 1 16 75 1 4 85 5 8 96 Angle Dia 8 12 18 24 36 48 45 6 8 Offset 10 5 16 13 3 16 17 3 8 21 5 8 30 1 8 38 5 8 Rise 17 13 16 20 5 8 24 7 8 29 1 8 37 5 8 46 1 8 Two lengths between elbows 8...

Page 5: ...int 6 7 8 Wall support 30 28 26 Adjust wall tee support 30 28 26 Roof support 20 18 16 Offset support 18 16 14 Cathedral support 30 28 26 Sq cathedral support 30 28 26 Finish support 30 28 26 Offset Wall support 24 21 20 Reduced Clearance support 30 28 26 SIZE OF OPENINGS Hole size framing Ø int 6 7 8 Roof support 14 15 16 Radiation shield 14 15 16 Cathedral support 14 3 8 14 3 8 14 3 8 Sq cathedr...

Page 6: ...y always requires the male coupler to be positioned upwards Size the chimney in accordance with the appliance instruction manual Map out the chimney path closest to the heating unit For wood stove applications a third pipe premium shield is required for inside installation where the chimney is enclosed between two floors see premium shield accessories section Prior to installation consult the deta...

Page 7: ...re minimal which stabilizes at high temperatures Reduces condensation and creosote buildup Low surface temperature Minimum 2 inch safety clearance to combustible materials in all diameters Fast venting of combustion products Delivers a stable and powerful draft Stainless steel outer casing Supports the structural load Corrosion resistance Inner liner attached only to the male coupler Free floating...

Page 8: ...ows 8 48 12 48 18 48 24 48 36 48 48 48 Offset 30 13 16 32 13 16 35 13 16 38 13 16 44 13 16 50 13 16 Rise 60 9 16 64 69 1 4 74 7 16 84 13 16 95 1 4 Angle Dia 8 12 18 24 36 48 45 6 8 Offset 10 5 16 13 3 16 17 3 8 21 5 8 30 1 8 38 5 8 Rise 17 13 16 20 5 8 24 7 8 29 1 8 37 5 8 46 1 8 Two lengths between elbows 8 48 12 48 18 48 24 48 36 48 48 48 Offset 43 7 16 46 1 4 50 1 2 54 3 4 63 1 4 71 11 16 Rise ...

Page 9: ...e wall support 63 63 55 48 39 Roof support 42 34 27 24 20 Offset support 28 24 20 14 Sq cathedral support 60 50 45 35 Finishing support 75 65 59 Adj square support w faming arms and coupler 27 22 Offset Wall support 28 24 20 14 Reduced Clearance support 60 50 45 SIZE OF OPENINGS Hole size framing Ø int 5 6 7 8 10 Floor support 11 3 8 12 3 8 13 3 8 14 3 8 16 3 8 Sq cathedral support 14 3 8 14 3 8 1...

Page 10: ...ty 36 36 length MI Insulated wall 30 30º angle Wall Support Kit for 6 7 Diameters Kit includes Insulated tee twist lock tee cap adjustable tee support insulated wall radiation shield flue extension double wall decorative collar wall band and rain cap Can use for through the wall installations Pipe not included ASHT Ref 6WSK 7WSK Only available in 6 7 Diameters Exterior Kit for 6 7 Diameters Kit in...

Page 11: ...ilable in 6 Diameter S2100 Ref 6XKI 7XKI Only available in 6 Diameter Interior New Construction Kit Kit includes Finishing support with removable outer trim collar adjustable insulated attic radiation shield and rain cap Use for new home construction with through the roof installation ASHT Ref 6IKNC Only available in 6 Diameter 800 361 4909 US 800 667 3387 Canada 10 ...

Page 12: ... 12 Lb ft 8 9 9 9 10 9 A 1 1 1 Length Available Effective Length Ø 6 to 8 8 7 12 11 18 17 24 23 36 35 48 47 Adjustable Lengths 5 60 A support must be installed within this area 3 min overlap 11 1 4 A A support must be installed within this area Used in combination with straight insulated lengths the adjustable length makes it possible to fit a Secure Temp length perfectly IMPORTANT The adjustable ...

Page 13: ... offsets 4 elbows is allowed ASHT Ref E30 Ø int 5 6 7 8 10 Ø ext 7 8 9 10 12 Lb ft 2 2 2 2 2 A 7 1 2 7 1 2 7 1 2 7 1 2 7 1 2 S2100 Ref XE30 Ø int 6 7 8 Ø ext 10 11 12 A 1 15 16 1 15 16 1 15 16 B 7 5 16 7 5 16 7 5 16 45º Insulated Elbow A B Allows the 45 offset of a chimney Designed to bypass an obstacle such as a joist A maximum of two offsets 4 elbows is allowed The chimney s angle of inclination...

Page 14: ...vide access for inspection and cleaning ASHT S2100 Ref TBD Ø int 6 7 8 10 A 31 33 35 39 B 18 18 1 2 19 20 C 5 5 1 2 6 7 D 5 1 2 6 6 1 2 7 1 2 E 8 9 10 12 Insulated Tee A C B Located at the base of the chimney it provides the horizontal connection to the appliance It is recommended for installations where a connector must pass through an exterior wall because its insulation prevents the cooling of ...

Page 15: ...on Must be combined with an adjustable wall support only ASHT Ref TCP Ø int 6 7 8 10 Supports Finishing Support A B C D E F This part supports the chimney from a ceiling Designed to connect to both double wall and single wall stove pipe it is enhanced by a decorative black finish Fits between standard 16 on center joists Must be attached to a frame built from the joists Refer to chart on pg 4 or 8...

Page 16: ... hole to be cut in the ceiling Can connect to both double wall stove pipe or single wall stove pipe with included adapter Functions as both an Attic Insulation Shield and Finishing Support An adjustable black finish trim insulation pad and collar are included Refer to chart on page 4 or 8 for loadbearing capacity A D C B E S2100 Ref XSCC Ø int 6 7 8 A 14 3 8 14 3 8 14 3 8 B 6 1 4 7 1 4 8 1 4 C 3 3...

Page 17: ...This support is used with a chimney that is passing through an angled cathedral ceiling Fits between standard 16 on center joists Designed to connect to both double wall and single wall stove pipe An adjustable black finish trim in included Refer to chart on page 4 or 8 for loadbearing capacity B A D C ASHT Ref SSC24 Ø int 6 7 8 A 6 15 64 7 1 4 8 1 4 B 12 14 3 8 14 3 8 C 24 24 24 D 2 2 2 S2100 Ref...

Page 18: ...s designed with a male coupler to accommodate the first section of the chimney This tee support is made of galvanized steel and must be installed with the insulated tee cap TCS included with the insulated tee ASHT Ref SM Ø int 6 7 8 10 A 19 19 19 16 B 13 13 13 16 C 16 16 16 16 S2100 Ref XSM Ø int 6 7 8 A 18 18 18 B 14 1 2 16 16 C 16 16 16 Square Cathedral Support Extention This part is designed to...

Page 19: ...o 5 Adjustable Wall Support A D B C This part supports the chimney at the base of the installation or along a wall or other vertical surface serving as an intermediate support It comes with a tightening collar that locks around the chimney and is secured by two self tapping screws included The collar rests on a horizontal plate When used as a base support it lends itself to the addition of a Twist...

Page 20: ...entary support is usually attached to a roof structure It is designed to support the chimney from the roof adjusting to any roof pitch above an offset when the chimney height exceeds the loadbearing capacity of the primary support Two adjustable plates screwed to the structure adapt to the pitch of the roof A tightening collar is attached and locks around the chimney It is secured by self tapping ...

Page 21: ...8 Anchor Plate A B D C This part is attached to a masonry or metal casing fireplace to provide a proper connection to the chimney It can also serve to connect a furnace Refer to the chart on pg 4 or 8 for loadbearing capacity ASHT Ref SP Ø int 5 6 7 8 10 A 5 6 7 8 10 B 12 12 12 12 14 C 2 2 2 2 2 D 3 3 3 3 3 S2100 Ref XSP Ø int 6 7 8 A 6 7 8 B 14 14 14 C 2 2 2 D 3 3 3 Flue Extension B A Fitted to t...

Page 22: ...X 48 MIN Used as a casing shield around the chimney only where it is enclosed inside a building for example between floors or in a chase It attaches with screws to a radiation shield connector at each floor ceiling ASHT Ref TRS Ø int 6 7 8 Flexible Shield B EXT A EXT 40 9 32 MIN 108 MAX Designed for use in the same applications as a rigid shield where an offset is required ASHT Ref FS Ø int 6 7 8 ...

Page 23: ... the top in an attic installation ASHT Ref SRS Ø int 6 7 8 A ext 10 13 32 11 13 32 12 13 32 Radiation Shield Connector Firestop A B ØC w ASHT Ref RCSP Ø int 6 7 8 A 16 16 16 B 12 13 14 C 10 21 32 11 21 32 12 21 32 Radiation Shield Connector Support B ØA Used in conjunction with a radiation shield connector SRS on floors where the chimney needs to be supported for example after an offset ASHT Ref R...

Page 24: ...collar included ASHT Ref RSA2 Ø int 5 6 7 8 10 A 11 12 13 14 16 B 11 12 13 14 16 C 12 12 12 12 12 D 16 16 16 16 18 S2100 Ref XRSA2 Ø int 6 7 8 A 14 15 16 B 14 15 16 C 12 12 12 D 16 18 18 Adjustable Insulated Attic Radiation Shield A B C 12 12 A A B Also referred to as an insulation shield this has the same features as the two piece insulated attic radiation shield but its height is adjustable from...

Page 25: ... D B C E This part is to be used only with the Security wood burning fireplace line and others that have been certified for use with the chimney It has been designed for use when the chimney passes through a wall at an angle ASHT Ref RSMI30 Ø int 6 7 8 10 A 36 3 4 39 1 4 41 1 4 44 13 16 B 17 1 8 18 1 8 19 1 8 20 1 8 C 15 1 8 16 1 8 17 1 8 18 1 8 D 34 3 4 37 1 4 39 1 4 42 13 16 E 3 3 3 3 Ref RSMI45...

Page 26: ... int 6 7 8 A 16 18 18 B 14 15 16 Universal Wall Band C A B Designed for use on an interior or exterior wall it serves to stabilize the chimney while providing the required clearance from the combustible surface The use of wall bands at maximum intervals of 8 is recommended Also available in 6 fix configuration 6BM ASHT Ref BM Ø int 5 6 7 8 10 A 7 8 9 10 12 B 19 21 23 25 29 C 2 2 2 2 2 S2100 Ref XB...

Page 27: ... Ref F Ø int 5 6 7 8 10 A 7 1 2 7 1 2 7 1 2 7 1 2 7 1 2 B 20 24 24 24 24 S2100 Ref XF Ø int 6 7 8 A 7 1 2 7 1 2 7 1 2 B 24 24 24 Peak Roof Flashing A B This component is required for chimney installations passing through the roof peak It is available in two models Peak roof 1 12 to 7 12 FP XFP Peak roof 8 12 to 12 12 FPB XFPB ASHT Ref FP FPB Ø int 6 7 8 10 Ref FPR A 3 5 8 3 5 8 3 5 8 3 5 8 B 12 13...

Page 28: ...6 36 Ref FBA A 6 6 3 8 6 7 8 B 36 36 36 S2100 Ref XFA XFB XFBB Ø int 6 7 8 Ref XFA A 6 6 6 B 24 24 28 Ref XFB A 3 7 8 3 7 8 4 1 2 B 24 24 30 Ref XFBB A 6 1 4 6 1 4 6 1 4 B 36 40 42 Storm Collar A Designed to fit over flashings it provides a weather tight seal It is automatically supplied with any roof flashings ASHT Ref FC Ø int 5 6 7 8 10 A 5 5 5 5 5 S2100 Ref XFC Ø int 6 7 8 A 5 5 5 Snow Diverte...

Page 29: ...0 Ref PE Universal piece fits all diameters Rain Cap Decorative Accessories Decorative Trim Ext Int The use of this decorative trim provides a flawless finish when a chimney must pass through a ceiling or any wall ASHT Ref PF Ø int 8 9 10 Ø Ext 17 20 20 S2100 Ref XPF Øint 8 9 10 Ø ext 20 20 20 Decorative Collar Single Wall C A B This component provides a finish between the Secure Temp chimney s fe...

Page 30: ... 12 12 Finishing Cone A A C When the chimney passes through an exterior wall a finishing cone may be used to conceal the protrusion of the insulated length 5 inside the dwelling A flue extension must be used to ensure a perfect connection between the chimney and the double wall black connector ASHT S2100 Ref PD Ø int 6 7 8 A 14 3 8 14 3 8 14 3 8 B 6 1 4 7 1 4 8 1 4 C 5 1 2 5 1 2 5 1 2 Decorative A...

Page 31: ...ducts using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from faulty installation or application of the Product This Limited Lifetime Warranty covers ...

Page 32: ...mer service specialists are ready to answer your questions 800 667 3387 or contact infoeng securitychimneys com EASHT S2100 LS304_Catalog_Secure Temp ASHT _S2100_03 25 20_V4 Security Chimneys International 2015 2017 Information published in all Security Chimneys literature is current at time of publication and is subject to change without notice www securitychimneys com 800 361 4909 US 800 667 338...

Reviews: