Introduction
XT30/XT50 User’s Guide
11
Zone Status
To display the status of a particular zone, enter the zone number
followed by the COMMAND key when the keypad displays the Status
List.
Armed Status
With Armed Status, the keypad displays the current armed condition
of areas within your security system.
The keypad displays
When
HOME SYSTEM ON
The perimeter areas is armed in a Home/
Away system.
PERIMETER ON
The perimeter is armed in an All/
Perimeter system.
ALL SYSTEM ON
All areas are on.
SLEEP SYSTEM ON
The perimeter and interior areas are on
but the bedroom area is off.
Also, for keypads that include an Armed LED, the Armed LED is ON
steady anytime a burglary protection area is armed and OFF when
ALL areas are disarmed.
Exit Error
This is an automatic panel function that occurs if an exit door does
not close all the way after the system is armed.
For example, if the front door is left ajar upon exit and the exit delay
time expires, the system attempts to arm the front door zone but
recognizes the open condition. The system sounds the alarm sirens
and starts the entry delay. If the open condition is not corrected, an
alarm and exit error is reported to the central station.
The Exit Error feature allows the central station to acknowledge
the arming error without dispatching the police on a false alarm.